Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WESTWOOD FABRICATION & SHEETMETAL,INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WESTWOOD FABRICATION & SHEETMETAL,INC. in 5870 WOLF CREEK PIKE, DAYTON, OH 45426 (NAICS 332312). OSHA activity number 330921719.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Westwood Fabrication & Sheetmetal,Inc. — free Get an email when a new federal OSHA severe-injury report for Westwood Fabrication & Sheetmetal,Inc. is published. One employer, no account, unsubscribe in one click.
Site address
5870 WOLF CREEK PIKE
City
DAYTON
State
OH
ZIP
45426
Mailing
5870 WOLF CREEK PIKE, DAYTON, OH 45426
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
14
Ownership type
A

3 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 20, 2011
Abate by
Nov 2, 2011
Penalty
Initial $2,400 · Current $1,680 Reduced
29 CFR 1910.147(c)(1):     The employer shall establish a program consisting of energy controlprocedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine orequipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall beisolated from the energy source and rendered inoperative.    a. In the main shop area, employees were performing maintenance work on machinery with there being no established energy control program in place.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2400

1910.147 C07 I

Serious Gravity 5 2 instances 1 exposed
Issued
Sep 20, 2011
Abate by
Nov 2, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i):     The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees.      b. In the main shop area, employees were performing maintenance activity without having received training in an energy control program.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 5 5 instances 1 exposed
Issued
Sep 20, 2011
Abate by
Nov 2, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i):     Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees.    c. In the main shop area, employees were engaged in maintenance activities, ie: belt and blade changes, without using lockout or tagout devices to isolate each energy source.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Westwood Fabrication & Sheetmetal,Inc.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330921719.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.