SUPERIOR, WI —
OSHA Inspection: WHITE CEDAR SHINGLES
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WHITE CEDAR SHINGLES in 2700 WINTER STREET, SUPERIOR, WI 54880 (NAICS 321999). OSHA activity number 330921859.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WHITE CEDAR SHINGLES
- Site address
- 2700 WINTER STREET
- City
- SUPERIOR
- State
- WI
- ZIP
- 54880
- Mailing
- 2700 WINTER STREET, SUPERIOR, WI 54880
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- Employees
- 8
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.213 H01
- Issued
- Aug 31, 2011
- Abate by
- Sep 8, 2011
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material: a) Blue Building, Cedar Siding trimming area, Dewalt model 770 radial arm saw; The guards to provide protection from the lower portion of the blade had been removed.
Recent events (1)
- — Z (S) $2400
1910.134 D01 III
- Issued
- Aug 31, 2011
- Abate by
- Sep 22, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminants chemical state and physical form: a) Blue Building, Staining Area; The employer did not conduct an evaluation of the staining area for potential respiratory hazards.
Recent events (1)
- — Z (O) $0
1910.1200 E01
- Issued
- Aug 31, 2011
- Abate by
- Sep 22, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): (Agriculture Reference: 1928.21(a)(5)) a) Throughout the facility: The employer did not develop and maintain a written hazardous communication program where workers were expose to chemical such as but not limited to, Miscellaneous oils and lubricants, Klean-Strip paint thinner and Cabot Bleaching Oil #3241.
Recent events (1)
- — Z (O) $0
More inspections at White Cedar Shingles
View White Cedar Shingles's full OSHA safety record →
More inspections in this industry (NAICS 321999)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330921859.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.