OSHA Inspection: CYCLONE DRILLING INC.

Programmed Other inspection · Safety discipline

On , OSHA opened a programmed Other safety inspection of CYCLONE DRILLING INC. in RIG #17 API 05-045-19478, RIFLE, CO 81650 (NAICS 213111). OSHA activity number 330922162.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cyclone Drilling INC. for free Get an email when a new federal OSHA severe-injury report for Cyclone Drilling INC. is published. One employer, no account, unsubscribe in one click.
Site address
RIG #17 API 05-045-19478
City
RIFLE
State
CO
ZIP
81650
Mailing
P.O. BOX 908, GILLETTE, WY 82717
Inspection type
Programmed Other (K)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
300
Ownership type
Private (A)

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 21, 2011
Abate by
Jan 5, 2012
Penalty
Initial $6,000 · Current $3,600 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards:     Cyclone Drilling, Inc. Drilling Rig 17, API 05-045-19478, Rifle, CO 81650: The employer did not maintain the condition of the flexible, high pressure hydraulic spinner hose, Spin Master's Model #550-H, for the rig floor. The hose was pinched against the spinner housing. The soft rubber cover was split open and bent exposing the hard hose line. This situation could lead to the failure of the hose due to lack of maintenance. This condition exposes employees to struck-by hazard.    Abatement Note: API 7K and 7L certification requires proper maintenance of the vibrating hoses.     Abatement Note:  Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (S) $3600
  • · Z (S) $6000

1910.212 A01

Serious Gravity 1 1 instance 6 exposed
Issued
Dec 21, 2011
Abate by
Jan 5, 2012
Penalty
Initial $2,805 · Current $1,683 Reduced
29 CFR 1910.212 (a)(1): The employer did not provide one or more methods of machine guarding to protect the operator and the other employees in the machine area from hazards such as those created by ingoing nip points and rotating parts:    (a) Cyclone Drilling, Inc., Drilling Rig 17, API 05-045-19478, Rifle, CO 81650: On and before July 7, 2011 the creating, exposing and correcting employer did not provide one or more methods of machine guarding to protect the operator and the other employees from the 2'' opening on the rotating shaft of the water pump. By not guarding the rotating parts on the water pump, employees were exposed to laceration hazards.    (b) Cyclone Drilling, Inc., Drilling Rig 17, API 05-045-19478, Rifle, CO 81650: On and before July 7, 2011 the creating, exposing and correcting employer did not provide one or more methods of machine guarding to protect the operator and the other employees from the 2'' opening on the rotating shaft of the new portable chemical transfer pump from the blender to the mud tanks. By not guarding the rotating parts on the chemical transfer pump, employees were exposed to laceration hazards.    (c) Cyclone Drilling, Inc., Drilling Rig 17, API 05-045-19478, Rifle, CO 81650: On and before July 7, 2011 the creating, exposing and correcting employer did not provide one or more methods of guarding to protect the operator and the other employees from ingoing nip points on the orange pneumatic, air winch, Model XJFH-5/35.  This winch is positioned at the top of the steps leading to the rig floor and is approximately 4 feet off the rig floor.  This condition exposed employees to caught-in hazards.      Abatement Note: Abatement certification and documentation are required for this item (see enclose Corrective Action Worksheet).
Recent events (2)
  • · I (S) $1683
  • · Z (S) $2805

1910.23 A09

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 21, 2011
Abate by
Jan 5, 2012
Penalty
Initial $4,675 · Current $2,805 Reduced
29 CFR 1910.23 (a)(9): The employer did not guard the floor holes into which persons cannot accidentially walk (on account of fixed machinery, equipment, or walls) shall be protected by a cover that leaves no openings more than 1 inch wide. The cover shall be securlely held in place to prevent tools or materials from falling through:    (a) Cyclone Drilling, Inc., Drilling Rig 17, API 05-045-19478, Rifle, CO 81650: On and before July 7, 2011 the creating, exposing and correcting employer did not guard six circular openings of approximately 9'' diameter on the mud tank floor. These hole openings have 14'' rods sticking out of them as well. This condition exposed employees to slip, trip, and fall hazards.    Abatement Note: Abatement certification and documentation are required for this item (see enclose Corrective Action Worksheet).
Recent events (2)
  • · I (S) $2805
  • · Z (S) $4675

1910.151 C

Deleted Other-than-serious 1 instance 6 exposed
Issued
Dec 21, 2011
Abate by
Jan 5, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.151 (c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    (a) Cyclone Drilling, Inc., Drilling Rig 17, API 05-045-19478, Rifle, CO 81650: On and before July 7, 2011 the creating, exposing and correcting employer did not provide suitable facilities for quick drenching and flushing the body with a shower to employees working with corrosive, liquid ammonium bisulfite 60% and sodium hydroxide. This condition exposed employees to chemical burns.    Abatement Note: For details on emergency eyewash and shower equipment, OSHA references the American National Standard for Emergency Eyewash and Shower Equipment, ANSI Z358.1.     (Abatement Note: Abatement certification and documentation are required for this item (see enclose Corrective Action Worksheet).
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.132 A

Deleted Other-than-serious 1 instance 6 exposed
Issued
Dec 21, 2011
Abate by
Jan 5, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.132 (a): The employer did not make sure that personal protective equipment (PPE) was maintained in a reliable condition wherever it is necessary by reason of hazards or processes in a manner capable of causing injury or impairment in the function of any part of the body through physical contact:    (a) Cyclone Drilling, Inc., Drilling Rig 17, API 05-045-19478, Rifle, CO 81650: On and before July 7, 2011 the creating, exposing and correcting employer did not maintain the Sala D621241206 or double leg climbing lanyard, MSA10072475, EZ Stop II, used for fall protection. The lanyard was frayed and torn near the D-ring. This condition exposed employees to fall hazards.    (Abatement Note: Abatement certification and documentation are required for this item (see enclose Corrective Action Worksheet).