TRINIDAD, CO ·
OSHA Inspection: HALLIBURTON ENERGY SERVICES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HALLIBURTON ENERGY SERVICES in HR-02-08, SEC: TWN: RNG, TRINIDAD, CO 81082 (NAICS 211111). OSHA activity number 330922360.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HALLIBURTON ENERGY SERVICES
- Site address
- HR-02-08, SEC: TWN: RNG
- City
- TRINIDAD
- State
- CO
- ZIP
- 81082
- Mailing
- 2928 FREEDOM RD., TRINIDAD, CO 81082
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 211111
- Employees
- 19
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 4, 2011
- Abate by
- Oct 6, 2011
- Penalty
- Initial $5,000 · Current $0 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to explosion/fire hazards. a) On or about June 29, 2011 and at times prior, Halliburton Energy Services did not ensure that employees were protected from explosion/fire hazards. 1. Signage warning of electrical device usage at the entry to well site was not maintained or displayed. 2. The proper number and size of fire extinguishers was not maintained at explosives transport truck. 3. The bed of the truck used to transport the explosives was not spark proof. 4. No straps or other method was used to secure the explosives in the truck bed. 5. Flammable items (cans of spray paint) were stored and transported with the igniters and explosives. Among other methods one feasible and acceptable abatement method is to follow the standards of the industry as llisted by Colorado State Division of Oil and Public Safety, Explosive Regulations Chapter V.
Recent events (2)
- · I (S) $0
- · Z (S) $5000
1910.23 C01
- Issued
- Oct 4, 2011
- Abate by
- Jan 6, 2012
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides: a) On or about June 29, 2011, Halliburton Energy Services did not ensure that employees were protected from fall hazards. Employees removing and replacing sections of flexible piping, from the top of the jell hydro tank, were exposed to falls of over 10 feet.
Recent events (2)
- · I (O) $5000
- · Z (S) $5000
1910.157 C04
- Issued
- Oct 4, 2011
- Abate by
- Jan 6, 2012
- Penalty
- Initial $7,000 · Current $6,000 Reduced
General-duty citation text
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition: a) On or about June 29, 2011, Halliburton Energy Services did not ensure that employees were protected from fire hazards. Fire extinguishers were placed out for use which had been used and were in a discharged state. Other extinguishers were missing pins, keepers, discharge bells on hoses, and had broken cases.
Recent events (2)
- · I (O) $6000
- · Z (S) $7000
1910.157 E02
- Issued
- Oct 4, 2011
- Abate by
- Oct 5, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: a) On or about June 29, 2011, Halliburton Energy Services did not ensure that employees were protected from fire/explosion hazards. The fire extinguishers provided on site were not given a monthly inspection to assure the extinguishers would work if needed.
Recent events (2)
- · I (O) $0
- · Z (S) $0
1910.157 E03
- Issued
- Oct 4, 2011
- Abate by
- Jan 6, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: a) On or about June 29, 2011, Halliburton Energy Services did not ensure that employees were protected from fire/explosion hazards. Fire extinguishers provided for protection on this site were not given annual maintenance checks.
Recent events (2)
- · I (O) $0
- · Z (S) $0
1910.219 D01
- Issued
- Oct 4, 2011
- Abate by
- Oct 5, 2011
- Penalty
- Initial $5,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o) a) On or about June 29, 2011 and at times prior, Halliburton Energy Services did not ensure that employees were protected from power-transmission apparatus hazards. Due to heating problems the hoods of trucks were raised and left open. This exposed the belt and pulley apparatus on the motor fans.
Recent events (2)
- · I (S) $0
- · Z (S) $5000
1910.219 E03 I
- Issued
- Oct 4, 2011
- Abate by
- Oct 5, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o) a) On or about June 29, 2011 and at times prior, Halliburton Energy Services did not ensure that employees were protected from power-transmission apparatus hazards. The hoods of trucks were opened to keep the motors from overheating. This allowed the belt and pulleys of the fan belt to be exposed to employees on site.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Halliburton Energy Services
View Halliburton Energy Services's full OSHA safety record →
More inspections in this industry (NAICS 211111)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 330922360.