BROOKLYN, OH —
OSHA Inspection: C. R. HOILES MASONRY INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of C. R. HOILES MASONRY INC. in 10700 BROOKPARK RD, BROOKLYN, OH 44144 (NAICS 238140). OSHA activity number 330923541.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- C. R. HOILES MASONRY INC.
- Site address
- 10700 BROOKPARK RD
- City
- BROOKLYN
- State
- OH
- ZIP
- 44144
- Mailing
- 12369 HOOVER AVE., UNIONTOWN, OH 44685
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 7
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 E01
- Issued
- Aug 10, 2011
- Abate by
- Aug 11, 2011
- Penalty
- Initial $1,980 · Current $1,188 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portableladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps,walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall beused. Crossbraces shall not be used as a means of access. On or about 07/15/11 during masonry activities, the employer did not ensure employees did not climb the ended frames on a fabricated scaffold while descending the scaffold. On or about 07/16/11 during scaffold dismantling activities, the employer did not ensure employees did not climb the end frames while lowering a scaffold plank to another level.
Recent events (2)
- — I (S) $1188
- — Z (S) $1980
1926.501 B01
- Issued
- Aug 10, 2011
- Penalty
- Initial $2,640 · Current $1,584 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and verticalsurface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrailsystems, safety net systems, or personal fall arrest systems. On or about 07/15/11 during masonry activities, the employer did not ensure employees were protected from a fall of approximately 13 feet by using fall protection systems/devices. On or about 07/16/11 during masonry activities, the employer did not ensure employees were protected from a fall of approximately 13 feet by using fall protection systems/devices.
Recent events (2)
- — I (S) $1584
- — Z (S) $2640
1926.451 G01
- Issued
- Aug 10, 2011
- Abate by
- Aug 11, 2011
- Penalty
- Initial $5,280 · Current $3,168 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected fromfalling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employeeson each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs,and other elevated surfaces are set forth in subpart M of this part. On or about 07/15/11 during masonry activities, the employer did not ensure employees were protected from a fall of approximately 13.8 feet by using fall protection systems/devices while working from a fabricated frame scaffold. C. R. HOILES MASONRY INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1926.451(G)(1), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314603796, CITATION NUMBER 01, ITEM NUMBER 01 AND WAS AFFIRMED AS A FINAL ORDER ON 07/02/10, WITH RESPECT TO A WORKPLACE LOCATED AT 2170 W 117TH. ST., CLEVELAND, OHIO. 44111.
Recent events (2)
- — I (R) $3168
- — Z (R) $5280
1910.178 L06
- Issued
- Aug 10, 2011
- Abate by
- Aug 24, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation. On or about 07/15/11 during masonry activities, the employer did not ensure a forklift operator had a current certification.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.451 B01 I
- Issued
- Aug 10, 2011
- Abate by
- Aug 11, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricatedplatform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are usedto extend the width of the platform). On or about 07/15/11 during masonry activities, the employer did not ensure a fabricated frame scaffold was fully planked at the working level.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.1053 B01
- Issued
- Aug 10, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On or about 07/15/11 during masonry activities, the employer did not ensure a portable ladder that was used to gain access to a roof was extended three feet above the upper landing surface or had a grab bar and was secured to prevent displacement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.1053 B04
- Issued
- Aug 10, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed. On or about 07/15/11 during masonry activities, the employer did not ensure a portable step ladder that was used to gain access to a roof was in the open position as the manufacture had intended for use.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at C. R. Hoiles Masonry INC.
View C. R. Hoiles Masonry INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330923541.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.