CARY, IL —
OSHA Inspection: AL'S WELDING & FABRICATION INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of AL'S WELDING & FABRICATION INC. in 1090 ALEXANDER COURT, CARY, IL 60013 (NAICS 332999). OSHA activity number 330923566.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AL'S WELDING & FABRICATION INC.
- Site address
- 1090 ALEXANDER COURT
- City
- CARY
- State
- IL
- ZIP
- 60013
- Mailing
- 1090 ALEXANDER COURT, CARY, IL 60013
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A03 II
- Issued
- Jan 11, 2012
- Abate by
- Jan 26, 2012
- Penalty
- Initial $3,000 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Accurshear Shear Machine (B837510), foot pedal operation. The openings in the point of operation guard were too large and did not prevent employees' hands from entering the point of operation of the shear blade while cutting various size pieces of sheet metal. Abatement documentation and certification is not required for this instance. Corrected During Inspection. b) Uni-Hydro 80 Ton Iron Worker Machine, foot pedal operation. The point of operation was not guarded at the punching station to prevent employees' hands from entering the point of operation while punching holes in small pieces of sheet metal. Abatement documentation is required for this instance in accordance with 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $2100
- — Z (S) $3000
1910.178 L06
- Issued
- Jan 11, 2012
- Abate by
- Feb 10, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): The employer did not certify that powered industrial truck operators had received a performance evaluation (driving test) at least once every three years. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at AL'S Welding & Fabrication INC.
View AL'S Welding & Fabrication INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330923566.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.