OSHA Inspection: KELLERMAN POWDER COATING, INC.

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of KELLERMAN POWDER COATING, INC. in 3543 U.S. RT 51, DU QUOIN, IL 62832 (NAICS 332813). OSHA activity number 330924481.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kellerman Powder Coating, INC. — free Get an email when a new federal OSHA severe-injury report for Kellerman Powder Coating, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3543 U.S. RT 51
City
DU QUOIN
State
IL
ZIP
62832
Mailing
3543 U.S. RT 51, DU QUOIN, IL 62832
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
5
Ownership type
A

4 citations on file for this inspection.

1910.303 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 5, 2012
Penalty
Initial $2,040 · Current $1,020 Reduced
29 CFR 1910.303(b)(1):     Examination. Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined using the following considerations:    Conductive equipment capable of causing arcing effects was stored inside a control panel for the spray booth dust collector.
Recent events (2)
  • — I (S) $1020
  • — Z (S) $2040

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 5, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2):     'Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.    Employees were exposed to electrical shock hazards when a piece of wire hanger was used as a means to open three breaker switches at once in the main high voltage electrical breaker panel outside of spray booth #2.
Recent events (1)
  • — Z (S) $0

1910.107 I04

Repeat Gravity 5 2 instances 1 exposed
Issued
Jan 5, 2012
Penalty
Initial $4,800 · Current $2,400 Reduced
29 CFR 1910.107(i)(4):     Electrical support equipment. Transformers, powerpacks, control apparatus, and all other electrical portions of the equipment, with the exception of the handgun itself and its connections to the power supply shall be located outside of the spraying area or shall otherwise conform to the requirements of paragraph (c) of this section.    Electrical light switches and associated receptacles in the spray booths spraying black powder (the two booths to the left of the wash bay) did not conform to the Class II Division 2 electrical requirements, potentially exposing employees to combustible dust ignition hazards.    Repeat:  Kellerman Powder Coating, Inc. was previously cited for a violation of this Occupational Safety and Health Standard, or its equivalent standard, 29 CFR 1910.107(i)(4), which was contained in OSHA Inspection Number 313015620.  Citation 1 - Item 2, and was affirmed as a Final Order on 12/15/2010, with respect to a workplace located at 3543 U.S. Route 51, DuQuoin, IL 62832.
Recent events (2)
  • — I (R) $2400
  • — Z (R) $4800

1910.1200 H01

Deleted Repeat Gravity 1 2 instances 2 exposed
Issued
Jan 5, 2012
Abate by
Jan 20, 2012
Penalty
Initial $3,600 · Current $0 Reduced

Hazardous substances E200

29 CFR 1910.1200(h)(1):     Employers shall provide employees with effective information and training on hazardous chemicals intheir work area at the time of their initial assignment, and whenever a new physical or health hazard the employees have not previously been trainedabout is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability,carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and material safety datasheets.    Employees did not receive training on hazardous materials upon initial assignment or when new products were introduced in their work areas and were exposed to chemical hazards from POWDURA powder coat paint in that employees were not trained on the potential explosive nature of the product.    Repeat:  Kellerman Powder Coating, Inc. was previously cited for a violation of this Occupational Safety and Health Standard, or its equivalent standard, 29 CFR 1910.1200(h)(1), which was contained in OSHA Inspection Number 313015620.  Citation 1 - Item 11, and was affirmed as a Final Order on 12/15/2010, with respect to a workplace located at 3543 U.S. Route 51, DuQuoin, IL 62832.
Recent events (2)
  • — I (R) $0
  • — Z (R) $3600

View Kellerman Powder Coating, INC.'s full OSHA safety record →