Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: M.K. PAINTING, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of M.K. PAINTING, INC in 5750 BLAZER PARKWAY, DUBLIN, OH 43017 (NAICS 238320). OSHA activity number 330925348.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M.K. Painting, INC — free Get an email when a new federal OSHA severe-injury report for M.K. Painting, INC is published. One employer, no account, unsubscribe in one click.
Establishment
M.K. PAINTING, INC
Site address
5750 BLAZER PARKWAY
City
DUBLIN
State
OH
ZIP
43017
Mailing
4157 SEVENTH ST., WYANDOTTE, MI 48192
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
5
Ownership type
A

6 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 23, 2011
Abate by
Aug 30, 2011
Penalty
Initial $4,620 · Current $1,848 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the frontuprights and the guardrail supports as follows:\\\\r\\\\n\\\\r\\\\n\\\\r\\\\nAt the worksite, employees were elevated approximately 130 feet from the ground and supported by a system scaffold that lacked full planking.
Recent events (2)
  • — I (S) $1848
  • — Z (S) $4620

1926.451 B06

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 23, 2011
Abate by
Sep 1, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(6): \\\\r\\\\n\\\\r\\\\nOn scaffolds where scaffold planks are abutted to create a long platform, each abutted end shallrest on a separate support surface. This provision does not preclude the use of common support members, such as \\\\\\\"T\\\\\\\" sections, to support abuttingplanks, or hook on platforms designed to rest on common supports.\\r\\n\\r\\nAt the worksite, the planks on a system scaffold approximately 150 feet in height overlapped one over the other which did not provide each abutting plank separate support.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F03

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 23, 2011
Abate by
Aug 30, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent personbefore each work shift, and after any occurrence which could affect a scaffold\\\\\\\'s structural integrity.\\\\r\\\\n\\\\r\\\\nAt the worksite, employees elevated approximately 130 feet and supported by system scaffold that was not fully planked, the scaffold did not have midrails on levels where employees were working, and abutting planks did not have separate supports.\\\\r\\\\n\\\\r\\\\n
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G04 III

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 23, 2011
Abate by
Sep 1, 2011
Penalty
Initial $4,620 · Current $1,848 Reduced
29 CFR 1926.451(g)(4)(iii): When midrails, screens, mesh, intermediate vertical members, solid panels, or equivalent structural members are used, they shall be installed between the top edge of the guardrail system and the scaffold platform.\\\\\\\\\\\\\\\\r\\\\\\\\\\\\\\\\n\\\\\\\\\\\\\\\\r\\\\\\\\\\\\\\\\nAt the worksite, a approximately 150 foot high system scaffold was not provided with midrails on the working level.
Recent events (2)
  • — I (S) $1848
  • — Z (S) $4620

1926.502 D21

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 23, 2011
Abate by
Aug 30, 2011
Penalty
Initial $4,620 · Current $1,848 Reduced
29 CFR 1926.502(d)(21): Personal fall arrest systems shall be inspected prior to each use for wear, damage and otherdeterioration, and defective components shall be removed from service.\\\\r\\\\n\\\\r\\\\nAt the worksite, personal fall protection in use by employees had frays and cuts in the body harnesses and lanyards.
Recent events (2)
  • — I (S) $1848
  • — Z (S) $4620

1926.501 B01

Repeat Gravity 10 1 instance 1 exposed
Issued
Aug 23, 2011
Abate by
Aug 30, 2011
Penalty
Initial $9,240 · Current $3,696 Reduced
29 CFR 1926.501(b)(1): \\\\\\\"Unprotected sides and edges.\\\\\\\" Each employee on a walking/working surface (horizontal and vertica lsurface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrailsystems, safety net systems, or personal fall arrest systems.\\\\r\\\\n\\\\r\\\\nAt the worksite, the employer did not ensure that employees who were working atop a water tower approximately 162 feet in height were protected from falling by guardrails, safety net, or personal fall arrest system.\\\\r\\\\n\\\\r\\\\nM.K. Painting, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(1), which was contained in OSHA inspection number 312853005, citation number 01, item number 001 and was affirmed as a final order on March 29, 2009, with respect to a workplace located at 13622 Centerbrook, Universal City, TX. 78150
Recent events (2)
  • — I (R) $3696
  • — Z (R) $9240

View M.K. Painting, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330925348.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.