Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KCH MECHANICAL, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of KCH MECHANICAL, INC. in 14456 E 1600TH AVE, EFFINGHAM, IL 62401 (NAICS 238220). OSHA activity number 330925660.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch KCH Mechanical, INC. — free Get an email when a new federal OSHA severe-injury report for KCH Mechanical, INC. is published. One employer, no account, unsubscribe in one click.
Site address
14456 E 1600TH AVE
City
EFFINGHAM
State
IL
ZIP
62401
Mailing
813 N. 3RD ST., P.O. BOX 345, EFFINGHAM, IL 62401
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
8
Ownership type
A

9 citations on file for this inspection.

1926.20 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 29, 2011
Abate by
Mar 15, 2012
Penalty
Initial $3,000 · Current $1,000 Reduced
29 CFR 1926.20(b)(1):     It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.    KCH Mechanical, Inc. had employees exposed to electrical hazards on a residential construction site in Effingham, Illinois. The employer did not have an effective safety program with specific work rules, competent person oversight, and employee training to govern employees' activities.    ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3000

1926.21 B02

Serious Gravity 5 3 instances 3 exposed
Issued
Dec 29, 2011
Abate by
Mar 15, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.21(b)(2):     The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.      KCH Mechanical, Inc. had employees exposed to electrical hazards on a residential construction site in Effingham, Illinois. The employer did not provide construction safety training to employees, in order to provide them with knowledge on the applicable safety rules and requirements as well as the proper work procedures to follow, in order to minimize and eliminate safety construction hazards.  		ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.307 D01

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 29, 2011
Abate by
Dec 30, 2011
Penalty
Initial $3,000 · Current $2,600 Reduced
29 CFR 1926.307(d)(1):     "Guarding."  Pulleys, any parts of which are 7 feet (2.128 m) or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section.  Pulleys serving as balance wheels(e.g., punch presses) on which the point of contact between belt and pulley is more than 6 ft., 6 in. (1.976 m) from the floor or platform may be guarded with a disk covering the spokes.      KCH Mechanical, Inc. had employees exposed to unguarded ingoing nip points of a pulley on a furnace blower/fan, on a residential construction site in Effingham, Illinois.    		ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $2600
  • — Z (S) $3000

1926.307 E01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 29, 2011
Abate by
Dec 30, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.307(e)(1)(i):     Where both runs of horizontal belts are 7 feet (2.128 m) or less from the floor level, the guard shall extend to at least 15 inches (38.1 cm) above the belt or to a standard height, except that where both runs of a horizontal belt are 42 inches (106.68 cm) or less from the floor, the belt shall be fully enclosed.      KCH Mechanical, Inc. had employees exposed to unguarded ingoing nip points on a belt of a furnace blower/fan, on a residential construction site in Effingham, Illinois.      		ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM
Recent events (1)
  • — Z (S) $0

1926.403 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 29, 2011
Abate by
Dec 30, 2011
Penalty
Initial $4,200 · Current $0 Reduced
29 CFR 1926.403(b)(1):     Examination. The employer shall ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees.      KCH Mechanical, Inc. had employees exposed to electrical hazards from the use of a furnace blower/fan, on a residential construction site in Effingham, Illinois. The employer did not ensure that electrical equipment was free from recognized hazards that were likely to cause death or serious physical harm.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4200

1926.405 G02 III

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 29, 2011
Abate by
Dec 30, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iii):     Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hardservice flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.      KCH Mechanical, Inc. had employees exposed to electrical hazards from the use of a furnace blower/fan, on a residential construction site in Effingham, Illinois. The employer had the electrical motor wiring of the furnace blower/fan spliced into a flexible cord, which was plugged into the two extension cords for electrical power.
Recent events (1)
  • — Z (S) $0

1926.405 G02 IV

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 29, 2011
Abate by
Dec 30, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv):     Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided, which will prevent pull from being directly transmitted to joints or terminal screws.    KCH Mechanical, Inc. had employees exposed to electrical hazards from the use of a furnace blower/fan, on a residential construction site in Effingham, Illinois. The equipment was provided electrical power thru an electrical extension cord that did not have adequate strain relief at the plug end.
Recent events (1)
  • — Z (S) $0

1926.404 B01 I

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 29, 2011
Abate by
Dec 30, 2011
Penalty
Initial $4,200 · Current $0 Reduced
29 CFR 1926.404(b)(1)(i):     General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.    KCH Mechanical, Inc. had employees exposed to electrical hazards from the use of a furnace blower/fan, on a residential construction site in Effingham, Illinois. The employer was using extension cords for electrical power, and the employer did not utilize ground fault protection, thru either ground fault circuit interrupters or an assured equipment grounding conductor program.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4200

1926.416 E01

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 29, 2011
Abate by
Dec 30, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1):     Worn or frayed electric cords or cables shall not be used.    KCH Mechanical, Inc. had employees exposed to electrical hazards from the use of a furnace blower/fan, on a residential construction site in Effingham, Illinois. For electrical power, the employer utilized an extension cord that had worn and cut outer insulation.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330925660.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.