OSHA Inspection: PEERLESS METAL PRODUCTS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PEERLESS METAL PRODUCTS in 6017 SUPERIOR AVENUE, CLEVELAND, OH 44103 (NAICS 332116). OSHA activity number 330926973.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Peerless Metal Products — free Get an email when a new federal OSHA severe-injury report for Peerless Metal Products is published. One employer, no account, unsubscribe in one click.
Site address
6017 SUPERIOR AVENUE
City
CLEVELAND
State
OH
ZIP
44103
Mailing
6017 SUPERIOR AVENUE, CLEVELAND, OH 44103
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332116
Employees
17
Ownership type
A

10 citations on file for this inspection.

1910.157 G02

Other-than-serious 1 instance 17 exposed
Issued
Dec 8, 2011
Abate by
Jan 24, 2012
Penalty
Initial $1,800 · Current $0 Reduced
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment and at least annually thereafter:    On 7/26/2011, the employer did not provide portable fire extinguisher training within the past 12 months.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1800

1910.212 A01

Serious Gravity 5 17 instances 3 exposed
Issued
Dec 8, 2011
Abate by
Jul 24, 2012
Penalty
Initial $3,000 · Current $1,800 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On 7/26/2011, the 17 Nilson four-slide machines and their associated uncoilers were not guarded.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3000

1910.217 C02 I A

Serious Gravity 5 5 instances 2 exposed
Issued
Dec 8, 2011
Abate by
Dec 30, 2011
Penalty
Initial $3,000 · Current $1,800 Reduced
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s):    On 7/26/2011, The Minster 70 ton and Minster 22 ton, 2 Federal 60 ton and the L & J 27 ton mechanical power presses were not adequately guarded in that the barrier guarding had openings in the front, at the sides and top including no guarding at the backsides.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3000

1910.303 G02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 8, 2011
Abate by
Dec 30, 2011
Penalty
Initial $1,800 · Current $1,080 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    On and before 7/26/2011, the Minster 70 ton mechanical power press high voltage control box had a relay for the automatic run mode that was not working properly, requiring the relay to be set by hand on the inside of the control box.
Recent events (2)
  • — I (S) $1080
  • — Z (S) $1800

1910.304 B02 II

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 8, 2011
Abate by
Dec 15, 2011
Penalty
Initial $1,800 · Current $1,080 Reduced
29 CFR 1910.304(b)(2)(ii): Receptacles and cord connectors which had grounding contacts did not have those contacts effectively grounded:    On 7/26/2011, the 304 four-slide machine had a duplex receptacle at the transformer with an open ground.
Recent events (2)
  • — I (S) $1080
  • — Z (S) $1800

1910.334 A02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 8, 2011
Penalty
Initial $1,800 · Current $0 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):    On 7/26/2011, the 201 four-slide machine had an electrical task light cord that had outer insulation damage.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1800

1910.1200 F05 I

Other-than-serious 3 instances 3 exposed
Issued
Dec 8, 2011
Abate by
Dec 30, 2011
Penalty
Initial $1,800 · Current $0 Reduced
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:      On 7/26 2011, the stationary metal working fluid containers used at the four-slide machines were not labeled with the product identity.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1800

1910.147 C06 I

Other-than-serious 1 instance 1 exposed
Issued
Dec 8, 2011
Abate by
Dec 30, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed:    On 7/26/2011, the employer had not conducted the lockout tagout periodic inspection within the past 12 months for machines such as but not limited to fourslide and mechanical power presses.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B07 IV

Other-than-serious 1 instance 3 exposed
Issued
Dec 8, 2011
Abate by
Dec 15, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:    On 7/26/2011, the 400 four-slide machine had a start control button that was damaged and open.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B01 II

Other-than-serious 3 instances 3 exposed
Issued
Dec 8, 2011
Abate by
Dec 15, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    On 7/26/2011, at the 300 four-slide machine there were two unused openings at the bottom of the disconnect switch and at the 203 four-slide machine there was an unused opening at the top of the disconnect switch.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Peerless Metal Products's full OSHA safety record →