AURORA, CO ·
OSHA Inspection: SANCHEZ, JAVIER
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SANCHEZ, JAVIER in 250 NORTH NEWBERN WAY, AURORA, CO 80018 (NAICS 238170). OSHA activity number 330926999.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SANCHEZ, JAVIER
- Site address
- 250 NORTH NEWBERN WAY
- City
- AURORA
- State
- CO
- ZIP
- 80018
- Mailing
- 13163 ROBINS DRIVE, DENVER, CO 80239
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 2
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
1926.502 B03
- Issued
- Aug 1, 2011
- Abate by
- Aug 22, 2011
- Penalty
- Initial $1,350 · Current $810 Reduced
General-duty citation text
29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge: a) Sanchez, Javier dba Gatos Construction at 250 North Newbern Way, Aurora, CO 80018: On or before 7/23/11, the employer did not ensure the 2 x 4 guardrails on the pump jack scaffold could withstand a force of at least 200 pounds at any point along the top edge, in that the posts used to support the guardrails were 14 feed apart. Condition exposed employees to a fall hazard of about 16 feet. Abatement note: Abatement certification is required for this item (See enclosed "Sample Abatement-Certification Letter"). Abatement note: Appendix B discusses Non-Mandatory Guidelines for complying with 1926.502(b), and references the need to place posts for 2 x 4 wood railings at not more than 8 feet apart.
Recent events (2)
- · I (S) $810
- · Z (S) $1350
More inspections in this industry (NAICS 238170)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 330926999.