Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: FOREMAN'S INSTALLATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FOREMAN'S INSTALLATION in CORNER OF DAY DR. & RIDGE RD., PARMA, OH 44129 (NAICS 238390). OSHA activity number 330927286.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Foreman'S Installation for free Get an email when a new federal OSHA severe-injury report for Foreman'S Installation is published. One employer, no account, unsubscribe in one click.
Site address
CORNER OF DAY DR. & RIDGE RD.
City
PARMA
State
OH
ZIP
44129
Mailing
404 CREST AVE, ELLWOOD CITY, PA 16117
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238390
Employees
1
Ownership type
A

3 citations on file for this inspection.

1926.501 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 10, 2011
Penalty
Initial $2,400 · Current $2,400
29 CFR 1926.501(b)(1): "Unprotected sides and edges. " Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.      On or about 07/27/11 during the installation of an awning, the employer did not ensure an employee was protected from a fall of approximately 12.3 feet by using fall protection systems/devices.
Recent events (1)
  • · Z (S) $2400

1926.1053 B13

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 9, 2011
Penalty
Initial $1,800 · Current $1,800
29 CFR 1926.1053(b)(13):     The top or top step of a step ladder shall not be used as a step.    On or about 07/27/11 during the installation of an awning, the employer did not ensure an employee did not stand on the top step of a portable step ladder.
Recent events (1)
  • · Z (S) $1800

1926.1053 B01

Other-than-serious 1 instance 1 exposed
Issued
Aug 9, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(1):     When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder.  In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.    On or about 07/27/11 during the installation of an awning, the employer did not ensure an employee that used a portable ladder to access an upper landing surface had the ladder extended three feet above the upper landing level.
Recent events (1)
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330927286.