OSHA Inspection: PRIMO IBARA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PRIMO IBARA in PLEASANT VALLEY ROAD, MIDDLETON, WI 53562 (NAICS 238160). OSHA activity number 330968736.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Primo Ibara for free Get an email when a new federal OSHA severe-injury report for Primo Ibara is published. One employer, no account, unsubscribe in one click.
Establishment
PRIMO IBARA
Site address
PLEASANT VALLEY ROAD
City
MIDDLETON
State
WI
ZIP
53562
Mailing
ROAD STAR INN 6900 SEYBOLD RD, MADISON, WI 53719
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

2 citations on file for this inspection.

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 3, 2011
Penalty
Initial $2,400 · Current $2,400
29 CFR 1926.1053(b)(1):     When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder.  In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.    The portable ladder used to access the roof did not extend 3 feet above the eave nor was it secured in place.
Recent events (1)
  • · Z (S) $2400

1926.1053 B16

Serious Gravity 1 1 instance 4 exposed
Issued
Aug 3, 2011
Abate by
Aug 17, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(16):     Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with "Do Not Use" or similar language, and shall be withdrawn from service until repaired.    The bottom two rungs of the portable ladder in use to access the roof were in disrepair.
Recent events (1)