Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WELLMAN BROTHERS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WELLMAN BROTHERS, INC. in 312 N. BROAD ST., KALIDA, OH 45853 (NAICS 238140). OSHA activity number 330969197.

Watch Wellman Brothers, INC. — free Get an email when a new federal OSHA severe-injury report for Wellman Brothers, INC. is published. One employer, no account, unsubscribe in one click.
Site address
312 N. BROAD ST.
City
KALIDA
State
OH
ZIP
45853
Mailing
310 S. THIRD ST., COLDWATER, OH 45828
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
7
Ownership type
A

3 citations on file for this inspection.

1926.300 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2040.00 · Current $1428.00 Reduced
29 CFR 1926.300(b)(1): Power operated tools when designed to accommodate guards, were not equipped with such guards when in use:    a) Wellman Brothers, Inc. on or about August 02, 2011, at the address of 312 N. Broad St. Kalida, OH:  The employer did not ensure a Bosch angle grinder was equipped with the appropriate factory provided guard while in use.  Employees were using the unguarded tool to grind masonry joints.  The employees were exposed to potential contact of the blade during grinding operations.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2040

1926.451 C02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2550.00 · Current $1785.00 Reduced
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.\r\n\r\na)  Wellman Brothers, Inc. on or about August 02, 2011, at the address of 312 N. Broad St. Kalida, OH: The employer failed to assure footings in which base plates and mud sills were placed were capable of supporting the scaffolding load. Mud sills (2x8 boards) supporting the load had begun to fracture due to the softer soil (footing) below. Employees working from this condition were exposed to a fall up to 130ft to the ground below.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2550

1926.452 C06

Serious Gravity 5 1 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $1785.00 Reduced
29 CFR 1926.452(c)(6): Scaffolds over 125 feet (38.0 m) in height above their base plates were not designed by a registered professional engineer, and constructed and loaded in accordance with such design.    a)  Wellman Brothers, Inc. on or about August 02, 2011, at the address of 312 N. Broad St. Kalida, OH: The employer failed to assure the 130ft tall scaffolding system used during masonry activities was designed by a registered professional engineer. Engineered plans would accurately identify erection specifications and limitations of use.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2550

View WELLMAN BROTHERS, INC.'s full OSHA safety record →