TORONTO, OH —
OSHA Inspection: MARGARETS CAFE
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MARGARETS CAFE in 805 NORTH FIFTH STREET, TORONTO, OH 43964 (NAICS 722410). OSHA activity number 330969817.
Where did this inspection happen?
- Establishment
- MARGARETS CAFE
- Site address
- 805 NORTH FIFTH STREET
- City
- TORONTO
- State
- OH
- ZIP
- 43964
- Mailing
- 805 NORTH FIFTH STREET, TORONTO, OH 43964
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 722410
- Employees
- 20
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $1800.00 · Current $1260.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. a) At the Margaret's Cafe located in Toronto, Ohio the employer had a 4 inch electrical box that housed the switches for the ventilation system above the stove and fryers that had a missing knockout.
Recent events (2)
- — I (S) $1260
- — Z (S) $1800
1910.305 B02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear. a) At the Margaret's Cafe in Toronto, Ohio there was an outlet receptacle located in the kitchen, underneath the dishwasher that was missing a cover.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $1800.00 · Current $1260.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used:\\n\\nAs a substitute for the fixed wiring of a structure;\n\na) At the Margaret\\\'s Cafe facility located in Toronto, Ohio, the employer had used an extension cord to bring power to the the cooler located next to the automatic dishwasher.\n\nb) At the Margaret\'s Cafe facility located in Toronto, Ohio, the employer had used multiple extension cords to bring power from the prep station over to the dishwasher's station in order to power a radio and three fans.
Recent events (2)
- — I (S) $1260
- — Z (S) $1800
1910.305 G02 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords may be used only in continuous lengths without splice or tap. Hard-service cord and junior hard-service cord No. 14 and larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced. a) At the Margaret's Cafe facility in Toronto, Ohio the employer had used multiple extension cords to power a radio at the prep cook station and three fans at the dishwasher's station.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(b)(2): \n\nEach exit must be clearly visible and marked by a sign reading \"Exit.\"\n\na) At the Margaret\'s Cafe located in Toronto, Ohio, the employer had an exit in the kitchen that was not marked with an exit sign.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 E03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(e)(3): \\n\\nThe employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request.\\n\\na) At the Margret\\\'s Cafe facility, the employer had fire extinguishers in the building that had not had an annual maintenance check since 2009.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 722410)
SEATTLE, WA—2026-06-15 00:00:00
WA317991697 - ROYAL HIDEOUT LLC
NEWPORT, OR—2026-05-15 00:00:00
317744155 - ROGUE RIVER BREWING COMPANY
TREMONT, IL—2026-05-14 00:00:00
PERDUE'S GRILL, INC.
ABERDEEN, WA—2026-05-06 00:00:00
WA317991097 - LANTZ RICHARD M
WASHINGTON, DC—2026-05-05 00:00:00
PROUST PARTNERS, LLC
More inspections in OH
WELLINGTON, OH—2026-07-16 00:00:00
WHIRLAWAY CORPORATION
WAUSEON, OH—2026-07-16 00:00:00
WATSON WELL DRILLING INC.
SEVEN HILLS, OH—2026-07-15 00:00:00
STONEY ACRES BUILDERS LLC
SEVEN HILLS, OH—2026-07-15 00:00:00
GRB ENTERPRISES LLC
CHILLICOTHE, OH—2026-07-15 00:00:00
KENWORTH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330969817.