GRAND CHUTE, WI —
OSHA Inspection: KEVIN JAENKE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KEVIN JAENKE in 4012 TOWNE LAKES CIRCLE, GRAND CHUTE, WI 54913 (NAICS 238160). OSHA activity number 330970765.
Where did this inspection happen?
- Establishment
- KEVIN JAENKE
- Site address
- 4012 TOWNE LAKES CIRCLE
- City
- GRAND CHUTE
- State
- WI
- ZIP
- 54913
- Mailing
- 935 LINDEN OAK DRIVE, OSHKOSH, WI 54901
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 1
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) Employee observed using pneumatic nailer to do roofing was not wearing safety glasses. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $2400
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) Employee doing roofing work on garage more then 6 feet above the ground was not protected from a fall with guard rail systems, safety net systems, or personal fall arrest system. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $2400
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder���s length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Extension ladder used to access roof on garage door side of the building did not extend at least 3 feet above roof access point. NO ABATEMENT CERTIFICATION OR DOCUMENTATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330970765.