TRINIDAD, CO ·
OSHA Inspection: BUILDING & STRUCTURAL ERECTORS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BUILDING & STRUCTURAL ERECTORS, LLC in 939 ROBINSON RD., TRINIDAD, CO 81082 (NAICS 236220). OSHA activity number 330971474.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BUILDING & STRUCTURAL ERECTORS, LLC
- Site address
- 939 ROBINSON RD.
- City
- TRINIDAD
- State
- CO
- ZIP
- 81082
- Mailing
- 4535 GOODNIGHT, PUEBLO, CO 81005
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 4
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.416 E01
- Issued
- Sep 2, 2011
- Abate by
- Sep 8, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) On or about August 5, 2011 and at times prior, employees were exposed to electrical hazards in that, damaged extension cords were in use at the site.
Recent events (1)
- · Z (S) $0
1926.501 B01
- Issued
- Sep 2, 2011
- Abate by
- Sep 8, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) On or about August 5, 2011, employees were exposed to fall hazards while walking and working from a pitched roof without fall protection in place or in use.
Recent events (1)
- · Z (S) $0
1926.1053 B04
- Issued
- Sep 2, 2011
- Abate by
- Sep 8, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) On or about August 5, 2011, employees were exposed to fall hazards while using a stepladder innappropriately where the ladder was leaned against a wall. Employees were then crawling through a window and onto a roof.