Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: BUILDING & STRUCTURAL ERECTORS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BUILDING & STRUCTURAL ERECTORS, LLC in 939 ROBINSON RD., TRINIDAD, CO 81082 (NAICS 236220). OSHA activity number 330971474.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Building & Structural Erectors, LLC for free Get an email when a new federal OSHA severe-injury report for Building & Structural Erectors, LLC is published. One employer, no account, unsubscribe in one click.
Site address
939 ROBINSON RD.
City
TRINIDAD
State
CO
ZIP
81082
Mailing
4535 GOODNIGHT, PUEBLO, CO 81005
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
4
Ownership type
Private (A)

3 citations on file for this inspection.

1926.416 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 2, 2011
Abate by
Sep 8, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:    a)  On or about August 5, 2011 and at times prior, employees were exposed to electrical hazards in that, damaged extension cords were in use at the site.
Recent events (1)
  • · Z (S) $0

1926.501 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 2, 2011
Abate by
Sep 8, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(1):  Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:    a)  On or about August 5, 2011, employees were exposed to fall hazards while walking and working from a pitched roof without fall protection in place or in use.
Recent events (1)
  • · Z (S) $0

1926.1053 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 2, 2011
Abate by
Sep 8, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:    a)  On or about August 5, 2011, employees were exposed to fall hazards while using a stepladder innappropriately where the ladder was leaned against a wall.  Employees were then crawling through a window and onto a roof.
Recent events (1)
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 330971474.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.