Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CHUCK MEADORS, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CHUCK MEADORS, INC in 2601 SOUTH RIDGE, ASHTABULA, OH 44004 (NAICS 327320). OSHA activity number 330973223.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Chuck Meadors, INC — free Get an email when a new federal OSHA severe-injury report for Chuck Meadors, INC is published. One employer, no account, unsubscribe in one click.
Establishment
CHUCK MEADORS, INC
Site address
2601 SOUTH RIDGE
City
ASHTABULA
State
OH
ZIP
44004
Mailing
2601 SOUTH RIDGE, ASHTABULA, OH 44004
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327320
Employees
9
Ownership type
A

6 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 27, 2011
Abate by
Jan 3, 2012
Penalty
Initial $2,400 · Current $1,200 Reduced
29 CFR 1910.147(c)(1): \\\\r\\\\n\\\\r\\\\nThe employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:\\\\r\\\\n\\\\r\\\\nThe company did not establish a program to protect employees involved with servicing and maintenance of machines and equipment from the unexpected energizing, start up or release of stored energy.  Energy sources included, but are not limited to, electrical, pneumatic, hydraulic, etc.  The company maintains and services equipment such as, but not limited to, punch machines, Three Bye Machine, etc.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1910.157 G02

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 27, 2011
Abate by
Oct 20, 2011
Penalty
Initial $1,800 · Current $900 Reduced
29 CFR 1910.157(g)(2):  The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:\\\\r\\\\n\\\\r\\\\nThe employer did not train employees on the use of portable fire extinguishers for those employees expected to fight incipient stage fires.\\\\r\\\\n\\\\r\\\\nNOTE:  The employer may exercise one of the following options:\\\\r\\\\n\\\\r\\\\n1)\\\\tProvide portable fire extinguishers as specified in 29 CFR 1910.157(c)(1), meet the distribution requirements per 29 CFR 1910.157(d) (75\\\\u0019 to the nearest extinguisher for Class A fires and 50\\\\u0019 to the nearest extinguisher for Class B fires), and provide training and education for all employees in the use of such equipment and the hazards associated with incipient stage fire fighting as required in 29 CFR 1910.157(g).  The other sections of 29 CFR 1910.157 also apply.\\\\r\\\\n\\\\r\\\\n2)\\\\tProvide extinguishers as specified in 29 CFR 1910.157(c) (1), designate certain employees to be the only employees authorized to use such equipment and require all other employees to immediately evacuate upon the sounding of the fire alarm, establish this in writing in an emergency action plan as outlined in 29 CFR 1910.38(c) and train/educate designated employees per 1910.157(g).  Utilizing this option exempts the employer from distribution requirements of 29 CFR 1910.157(d).\\\\r\\\\n\\\\r\\\\n3)\\\\t  Establish a written fire safety policy which requires the immediate and total evacuation of employees from the workplace upon the sounding of a fire alarm signal.  This policy includes an emergency action plan and a fire prevention plan as specified in 29 CFR 1910.38(a) and (b).  Utilizing this option exempts the employer from the requirements of 1910.157 to include the need for providing portable fire equipment unless a specific standard requires that a portable fire extinguisher be provided (such as those requirements in 29 CFR 1910.106/107 relating to use/storage of flammable/combustible liquids).  If extinguishers are provided but not intended for employee use, 29 CFR 1910.157(a) and (f) are still applicable (inspection, maintenance and testing of equipment).\\\\r\\\\n\\\\r\\\\n\\\\r\\\\n
Recent events (2)
  • — I (S) $900
  • — Z (S) $1800

1910.212 A03 II

Serious Gravity 5 4 instances 1 exposed
Issued
Sep 27, 2011
Abate by
Oct 11, 2011
Penalty
Initial $2,400 · Current $1,200 Reduced
29 CFR 1910.212(a)(3)(ii): \\\\r\\\\n\\\\r\\\\nPoint(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):\\\\r\\\\n\\\\r\\\\n(a)  The 05, 06 and 07 machine, did not have any point of operation guarding.\\\\r\\\\n\\\\r\\\\n(b)  The Three Bye Machine did not have any point of operation guarding.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1910.242 B

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 27, 2011
Abate by
Oct 4, 2011
Penalty
Initial $1,800 · Current $900 Reduced
29 CFR 1910.242(b): \\\\r\\\\n\\\\r\\\\nCompressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:\\\\r\\\\n\\\\r\\\\nCompressed air used for cleaning purposes on the Three Bye Machine was not reduced to 30 p.s.i.  The compressed air measured approximately 98 p.s.i. when dead-ended.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1800

1910.303 B07 IV

Other-than-serious 1 instance 1 exposed
Issued
Sep 27, 2011
Abate by
Oct 4, 2011
Penalty
Initial $1,800 · Current $0 Reduced
29 CFR 1910.303(b)(7)(iv): \\r\\n\\r\\nThere were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:\\r\\n\\r\\nThe electrical outlet box, mounted on the pillar by the Three Bye Machine, and which had a fan plugged into it, was damaged.  The conduit was broken free from the oulet box and the electrical outlet cover was bent away from its mounting.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1800

1910.305 G02 III

Other-than-serious 1 instance 1 exposed
Issued
Sep 27, 2011
Abate by
Oct 4, 2011
Penalty
Initial $1,800 · Current $0 Reduced
29 CFR 1910.305(g)(2)(iii): \\\\r\\\\n\\\\r\\\\nFlexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:\\\\r\\\\n\\\\r\\\\nThere was no strain relief provided for the coolng fan for the computer.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1800

View Chuck Meadors, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330973223.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.