DAYTON, OH —
OSHA Inspection: MILLAT INDUSTRIES, CORP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MILLAT INDUSTRIES, CORP in 4901 CROFTSHIRE DR., DAYTON, OH 45440 (NAICS 332721). OSHA activity number 330973876.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MILLAT INDUSTRIES, CORP
- Site address
- 4901 CROFTSHIRE DR.
- City
- DAYTON
- State
- OH
- ZIP
- 45440
- Mailing
- 4901 CROFTSHIRE DR., DAYTON, OH 45440
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332721
- Employees
- 125
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.137 B02 VIII
- Issued
- Sep 16, 2011
- Abate by
- Sep 30, 2011
- Penalty
- Initial $2,700 · Current $2,700
General-duty citation text
29 CFR 1910.137(b)(2)(viii): Electrical protective equipment shall be subjected to periodic electrical tests. Test voltages and the maximum intervals between tests shall be in accordance with Table I-5 and Table I-6. Insulated rubber gloves, Class OO, red, used by qualified employees had not been proof tested since they were purchased 1 1/2 years ago.
Recent events (2)
- — I (S) $2700
- — Z (S) $2700
1910.147 C06 I
- Issued
- Sep 16, 2011
- Abate by
- Sep 30, 2011
- Penalty
- Initial $4,500 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. Periodic inspections of the Company's energy control procedures had not been conducted at least annually.
Recent events (2)
- — I (S) $4000
- — Z (S) $4500
1910.147 C07 I
- Issued
- Sep 16, 2011
- Penalty
- Initial $4,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: a. An employee designated by the Company as an "authorized employee" had not received training upon hire or evaluated by the Company as to their knowledge and skills required for the safe application, usage, and removal of energy control devices. b. Employees who grease the chuck on an Okuma Lathe had not received training on the knowledge and skills required for the safe application, usage and removal of energy controls. c. Employees who clean the base plate on Muratec MD 120 SN 4524 had not received training on the knowledge and skills required for the safe application, usage and removal of energy controls.
Recent events (2)
- — I (S) $0
- — Z (S) $4500
1910.147 D04 I
- Issued
- Sep 16, 2011
- Abate by
- Sep 30, 2011
- Penalty
- Initial $4,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees. a. In the Production Area, VVT, the Muratec MD 120, SN 4524 electrical and pneumatic energy sources were not locked out while employee(s) open the plexiglass door at the beginning of the shift to clean the base plate in which a part was placed on by a robotic arm. b. In the Production Area the electrical energy source was not locked out while employee(s) greased the chuck on the Okuma Lathe. c. In the Production Area the pneumatic energy source was not locked out while employee(s) replaced the sensors on the tool changer of the Kitamura, My-Center 2, SN 11185.
Recent events (2)
- — I (S) $0
- — Z (S) $4500
1910.212 A03 II
- Issued
- Sep 16, 2011
- Abate by
- Sep 30, 2011
- Penalty
- Initial $4,500 · Current $1,300 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards,shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. In the Production Area the point of operation on the Leak Tester Machine exposed an employee to a crushing injury due to the presence sensing devices being located too close to the edge of the downward movement of the ram of the machine, 4", versus 5.5" as the calculated safe distance.
Recent events (2)
- — I (S) $1300
- — Z (S) $4500
1910.332 B01
- Issued
- Sep 16, 2011
- Abate by
- Oct 31, 2011
- Penalty
- Initial $4,500 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.332(b)(1): Employees shall be trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertain to their respective job assignments. Employee(s) who performed energized electrical work in the facility had not been trained as what and when to wear personal protective equipment to protect themselves against electric shock and arc flash.
Recent events (2)
- — I (S) $1000
- — Z (S) $4500
1910.334 A02 I
- Issued
- Sep 16, 2011
- Penalty
- Initial $2,700 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord and plug connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated. In the Custom Machining Area a floor fan (no manufacturer or model identified on fan) being used by employees during a period when the air conditioning was not working had a plug missing its ground pin and a section of internal insulated wiring was exposed due to the outer insulation being pulled away from the fitting.
Recent events (2)
- — I (S) $1000
- — Z (S) $2700
More inspections at Millat Industries, Corp
View Millat Industries, Corp's full OSHA safety record →
More inspections in this industry (NAICS 332721)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330973876.