Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,473Inspections Most recent open 2026-07-28 Last loaded 2026-07-31

OSHA Inspection: YENKIN-MAJESTIC PAINT CORP

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of YENKIN-MAJESTIC PAINT CORP in 1100 WOODLAND AVE, COLUMBUS, OH 43219 (NAICS 325510). OSHA activity number 330977166.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Yenkin-Majestic Paint Corp — free Get an email when a new federal OSHA severe-injury report for Yenkin-Majestic Paint Corp is published. One employer, no account, unsubscribe in one click.
Site address
1100 WOODLAND AVE
City
COLUMBUS
State
OH
ZIP
43219
Mailing
1920 LEONARD AVE, COLUMBUS, OH 43219
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325510
Employees
180
Ownership type
A

3 citations on file for this inspection.

1910.178 G02

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 27, 2011
Abate by
Jan 26, 2012
Penalty
Initial $4,500 · Current $2,700 Reduced
29 CFR 1910.178(g)(2):     Facilities shall be provided for flushing and neutralizing spilled electrolyte, for fire protection, for protecting charging apparatus from damage by trucks, and for adequate ventilation for dispersal of fumes from gassing batteries.    a) At the Yenkin-Majestic Paint Corporation in Columbus, Ohio, the warehouse had a Hobart Battery Charger (model # 865-c3-18, Serial # 389cs09135) that was sitting on a pallet on the floor, within two to three feet of where the forklifts drive and park on a daily basis, and was not protected from damage from the forklifts.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1910.305 G01 IV A

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 27, 2011
Abate by
Jan 26, 2012
Penalty
Initial $4,500 · Current $2,700 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used:    As a substitute for the fixed wiring of a structure;    a) At the Yenkin-Majestic Paint Corporation, the battery charging station in the warehouse had a Hobart battery charger (Model # 865c3-18, Serial # 389cs09135), that was sitting on a pallet on the floor.  The manufacturer of the battery charger required it to be securely mounted to concrete floor or a base.  The battery charger was powered using approximately 10 foot flexible cord (type SEOOW) instead of fixed wiring in conduit.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1910.24 H

Other-than-serious 1 instance 1 exposed
Issued
Dec 27, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.24(h):     "Railings and handrails." Standard railings shall be provided on the open sides of all exposed stairways and stair platforms. Handrails shall be provided on at least one side of closed stairways preferably on the right side descending. Stair railings and handrails shall be installed in accordance with the provisions of 1910.23.    a) At the Yenkin-Magestic Paint Corporation in Columbus, Ohio the entrance stairs to the warehouse facility, that were six risers in height, were not equipped with a mid-rail.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Yenkin-Majestic Paint Corp's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330977166.