WOOSTER, OH ·
OSHA Inspection: ADAMS WELDING
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ADAMS WELDING in 668 APPLECREEK ROAD, WOOSTER, OH 44691 (NAICS 811310). OSHA activity number 330977588.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADAMS WELDING
- Site address
- 668 APPLECREEK ROAD
- City
- WOOSTER
- State
- OH
- ZIP
- 44691
- Mailing
- 668 APPLECREEK ROAD, WOOSTER, OH 44691
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811310
- Employees
- 3
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1910.212 A01
- Issued
- Jan 10, 2012
- Abate by
- Jan 13, 2012
- Penalty
- Initial $1,800 · Current $900 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are barrier guards, two-hand tripping devices, electronic safety devices, etc: The back side of the Verson press brake was not guarded.
Recent events (2)
- · I (S) $900
- · Z (S) $1800
1910.219 D01
- Issued
- Jan 10, 2012
- Abate by
- Jan 13, 2012
- Penalty
- Initial $1,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punchpresses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes: A pulley that powered the Wysong shear was not guarded on the 4th side. The unguarded opening at the top that exposed the pulley was 44 inches from adjacent ground level.
Recent events (2)
- · I (S) $0
- · Z (S) $1800
1910.303 B01 I
- Issued
- Jan 10, 2012
- Abate by
- Jan 15, 2012
- Penalty
- Initial $2,400 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(i): Suitability for installation and use, in conformity with the provisions of this subpart; Note to paragraph (b)(1)(i) of this section: Suitability of equipment for an identified purpose may be evidenced by listing or labeling for that identified purpose: Two 3-phase electrical outlets (specifically junction boxes) were spliced onto an extension cord and used to power welding equipment.
Recent events (2)
- · I (S) $1200
- · Z (S) $2400
1910.305 G02 II
- Issued
- Jan 10, 2012
- Abate by
- Jan 15, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords may be used only in continuous lengths without splice or tap. Hard-service cord and junior hard-service cord No. 14 and larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced: A 3-phase flexible cord spliced with a single phase leg was used to power welding equipment.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.132 D02
- Issued
- Jan 10, 2012
- Abate by
- Feb 9, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment: The required workplace hazard assessment, designed to identify the personal protective equipment needed by employees to be safe, was not completed.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.157 G01
- Issued
- Jan 10, 2012
- Abate by
- Jan 25, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(1): Where the employer has provided portable fire extinguishers for employee use in the workplace, the employer shall also provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting: Employees expected to use ABC-type fire extinguishers as the second line of defense in fighting incipient-stage fires were not provided with extinguisher training.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.178 L06
- Issued
- Jan 10, 2012
- Abate by
- Jan 25, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation: Documentation showing the training and/or evaluation of the employees who operate lift truck(s) at the facility was not completed.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1200 E01
- Issued
- Jan 10, 2012
- Abate by
- Jan 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following: There was no written Hazard Communication program developed for employees exposed to hazardous chemicals in their work environment including but not limited to propane and welding materials.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Adams Welding
View Adams Welding's full OSHA safety record →
More inspections in this industry (NAICS 811310)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 330977588.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.