Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: ADAMS WELDING

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ADAMS WELDING in 668 APPLECREEK ROAD, WOOSTER, OH 44691 (NAICS 811310). OSHA activity number 330977588.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Adams Welding for free Get an email when a new federal OSHA severe-injury report for Adams Welding is published. One employer, no account, unsubscribe in one click.
Establishment
ADAMS WELDING
Site address
668 APPLECREEK ROAD
City
WOOSTER
State
OH
ZIP
44691
Mailing
668 APPLECREEK ROAD, WOOSTER, OH 44691
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
3
Ownership type
Private (A)

8 citations on file for this inspection.

1910.212 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 10, 2012
Abate by
Jan 13, 2012
Penalty
Initial $1,800 · Current $900 Reduced
29 CFR 1910.212(a)(1):  Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are barrier guards, two-hand tripping devices, electronic safety devices, etc:    The back side of the Verson press brake was not guarded.
Recent events (2)
  • · I (S) $900
  • · Z (S) $1800

1910.219 D01

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 10, 2012
Abate by
Jan 13, 2012
Penalty
Initial $1,800 · Current $0 Reduced
29 CFR 1910.219(d)(1):  Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punchpresses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes:    A pulley that powered the Wysong shear was not guarded on the 4th side.  The unguarded opening at the top that exposed the pulley was 44 inches from adjacent ground level.
Recent events (2)
  • · I (S) $0
  • · Z (S) $1800

1910.303 B01 I

Serious Gravity 5 1 exposed
Issued
Jan 10, 2012
Abate by
Jan 15, 2012
Penalty
Initial $2,400 · Current $1,200 Reduced
29 CFR 1910.303(b)(1)(i):  Suitability for installation and use, in conformity with the provisions of this subpart;  Note to paragraph (b)(1)(i) of this section: Suitability of equipment for an identified purpose may be evidenced by listing or labeling for that identified purpose:    Two 3-phase electrical outlets (specifically junction boxes) were spliced onto an extension cord and used to power welding equipment.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2400

1910.305 G02 II

Serious Gravity 5 1 exposed
Issued
Jan 10, 2012
Abate by
Jan 15, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii):  Flexible cords may be used only in continuous lengths without splice or tap. Hard-service cord and junior hard-service cord No. 14 and larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced:    A 3-phase flexible cord spliced with a single phase leg was used to power welding equipment.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.132 D02

Other-than-serious 1 exposed
Issued
Jan 10, 2012
Abate by
Feb 9, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2):  The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment:    The required workplace hazard assessment, designed to identify the personal protective equipment needed by employees to be safe, was not completed.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.157 G01

Other-than-serious 1 exposed
Issued
Jan 10, 2012
Abate by
Jan 25, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1):  Where the employer has provided portable fire extinguishers for employee use in the workplace, the employer shall also provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:    Employees expected to use ABC-type fire extinguishers as the second line of defense in fighting incipient-stage fires were not provided with extinguisher training.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.178 L06

Other-than-serious 1 exposed
Issued
Jan 10, 2012
Abate by
Jan 25, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6):  Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation:    Documentation showing the training and/or evaluation of the employees who operate lift truck(s) at the facility was not completed.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1200 E01

Other-than-serious 1 exposed
Issued
Jan 10, 2012
Abate by
Jan 31, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1):  Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following:    There was no written Hazard Communication program developed for employees exposed to hazardous chemicals in their work environment including but not limited to propane and welding materials.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Adams Welding's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 330977588.