Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: FIVE STAR LAUNDRY INC.

Unprogrammed Related inspection · Health discipline

On , OSHA opened an unprogrammed Related health inspection of FIVE STAR LAUNDRY INC. in 1060 W. DIVISION, CHICAGO, IL 60642 (NAICS 812332). OSHA activity number 330977786.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Five Star Laundry INC. for free Get an email when a new federal OSHA severe-injury report for Five Star Laundry INC. is published. One employer, no account, unsubscribe in one click.
Site address
1060 W. DIVISION
City
CHICAGO
State
IL
ZIP
60642
Mailing
1060 W. DIVISION, CHICAGO, IL 60642
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
812332
Employees
285
Ownership type
A

6 citations on file for this inspection.

1910.303 B02

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 23, 2011
Abate by
Nov 25, 2011
Penalty
Initial $4,000 · Current $2,000 Reduced
29 CFR 1910.303(b)(2): Listed or labeled equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) On or about August 1, 2011, at the above located workplace employees working just east of the sorting area were exposed to an energized 120 volt floor fan that lacked proper grounding. Employees were thereby exposed to the hazards associated with electric shock.
Recent events (2)
  • · I (S) $2000
  • · Z (S) $4000

1910.334 A03 II

Serious 1 instance 8 exposed
Issued
Nov 23, 2011
Abate by
Nov 25, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(3)(ii): Attachment plugs and receptacles were connected or altered in a manner which prevented proper continuity of the equipment grounding conductor at the point where plug(s) are attached to the receptacle(s):    a) On or about August 1, 2011, at the above located work place, employees working just east of the sorting area were exposed to an energized 120 volt floor fan which was missing a grounding pin. The employees using this equipment were thereby exposed to the hazards associated with electrical shock.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.335 A01 I

Serious Gravity 5 4 exposed
Issued
Nov 23, 2011
Abate by
Dec 15, 2011
Penalty
Initial $4,000 · Current $0 Reduced
29 CFR 1910.335(a)(1)(i): Employees working in areas where there was potential electrical hazards were not provided with, and/or did not use, electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed.    a) Between May 1, 2011 and August 1, 2011, at the above located work place, employees performing voltage testing on electrical equipment of 220 to 440 volts, were not provided and/or required to use personal protective equipment including but not limited to flame resistant clothing, leather gloves, voltage-rated gloves and double layer switching hoods or arc flash suit hoods when working on or near energized electrical (440 volt) parts. Employees were thereby exposed to hazards associated with energized electrical parts.
Recent events (2)
  • · I (S) $0
  • · Z (S) $4000

1904.32 B03

Other-than-serious 2 instances 40 exposed
Issued
Nov 23, 2011
Abate by
Nov 25, 2011
Penalty
Initial $0 · Current $0
29 CFR 1904.32(b)(3):  The Summary of Work-Related Injuries and Illnesses (OSHA Form 300A or equivalent) was not properly certified:    a) On or about August 1, 2011, at the above located workplace, the employers OSHA 300A summaries for 2009 and 2010 were not properly certified by a company executive.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.147 C04 I

Other-than-serious 3 exposed
Issued
Nov 23, 2011
Abate by
Dec 15, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    On or about April 29, 2011, at the above located workplace, the employer did not develop and implement specific procedures for equipment having more that one energy source such as the tunnel washer and the steam flat ironers.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 4 exposed
Issued
Nov 23, 2011
Abate by
Nov 25, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): Employers did not develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met:    a) On or about September 28, 2011, at the above located workplace, employees were exposed to hazards associated with chemicals such as, but not limited to, Zep Commercial Professional Strength Industrial Purple, Quimex Premium AW 68 Hydraulic oil and other hazardous chemicals. The employer did not maintain a written hazardous communication program.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330977786.