RICHLAND CENTER, WI —
OSHA Inspection: RICHLAND CENTER FOUNDRY
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of RICHLAND CENTER FOUNDRY in 1000 FOUNDRY DRIVE, EAST, RICHLAND CENTER, WI 53581 (NAICS 331511). OSHA activity number 330978602.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RICHLAND CENTER FOUNDRY
- Site address
- 1000 FOUNDRY DRIVE, EAST
- City
- RICHLAND CENTER
- State
- WI
- ZIP
- 53581
- Mailing
- 1000 FOUNDRY DRIVE EAST, RICHLAND CENTER, WI 53581
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331511
- Employees
- 150
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.23 D01
- Issued
- Jan 10, 2012
- Abate by
- Feb 20, 2012
- Penalty
- Initial $5,400 · Current $3,780 Reduced
General-duty citation text
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers were not equipped with standard stair railings or standard handrails. A flight of stairs with 4 risers in the pouring and dumper area did not have an standard stair railing or handrail. Abatement certification required per 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $3780
- — Z (S) $5400
1910.24 E
- Issued
- Jan 10, 2012
- Abate by
- Feb 20, 2012
- Penalty
- Initial $5,400 · Current $3,780 Reduced
General-duty citation text
29 CFR 1910.24(e): Fixed stairs were not installed at angles to the horizontal of between 30 deg. and 50 deg. A uniform combination of rise/tread dimensions were not used that would have resulted in a stairway at an angle to the horizontal within the permissible range. A set of stairs leading up to the metal deck were not evenly sized in height and depth to produce a uniform angle of rise/tread dimensions. Abatement certification required per 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $3780
- — Z (S) $5400
1910.134 D01 II
- Issued
- Jan 10, 2012
- Abate by
- Jan 20, 2012
- Penalty
- Initial $5,400 · Current $3,780 Reduced
General-duty citation text
29 CFR 1910.134(d)(1)(ii): The NIOSH-certified respirator was not used in compliance with the conditions of its certification. An employee working on the heavy grinding floor was observed performing job duties wearing a N95 respirator under a supplied air respirator. Abatement certification required per 29 CFR 1903.19(c)
Recent events (2)
- — I (S) $3780
- — Z (S) $5400
1910.252 B02 III
- Issued
- Jan 10, 2012
- Abate by
- Jan 20, 2012
- Penalty
- Initial $3,600 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers or other persons adjacent to the welding areas were not protected from welding rays by noncombustible or flameproof screens or shields. Employees working in the heat treat building were exposed to welding rays due to the lack of a welding curtain. Abatement certification required per 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $2520
- — Z (S) $3600
1910.1000 C
- Issued
- Jan 10, 2012
- Abate by
- Dec 20, 2015
- Penalty
- Initial $5,400 · Current $3,780 Reduced
General-duty citation text
29 CFR 1910.1000(c): Employee(s) were exposed to an airborne concentration of Respirable dust listed in Table Z-3 in excess of 10 mg/m3 (milligrams per cubic meter) as an 8 hour Time Weighted Average (TWA) concentration: (a) The grinder working on the heavy grinding floor was exposed to Respirable dust at an 8 hour time weighted average of 15.65 milligrams per cubic meter (mg/m3), approximately 1.04 times the limit of 15 mg/m3; this limit is established to prevent irritation of the eyes, skin, respiratory system, cough; metal fume fever; siderosis; and iron staining of the eyes. The sample was collected on October 11th, 2011 during a 442 minute sampling period; exposure calculations include a zero increment for the 38 minutes not sampled. (b) The grinder working on the heavy grinding floor was exposed to Respirable dust at an 8 hour time weighted average of 16.69 mg/m3, approximately 1.11 times the limit of 15 mg/m3; this limit is established to prevent irritation of the eyes, skin, respiratory system, cough; metal fume fever; siderosis; and iron staining of the eyes. The sample was collected on October 11th, 2011 during a 445 minute sampling period; exposure calculations include a zero increment for the 35 minutes not sampled. Abatement documentation required per 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $3780
- — Z (S) $5400
1910.1000 E
- Issued
- Jan 10, 2012
- Abate by
- Dec 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not implemented to reduce employee exposure(s): (a) The grinder working on the heavy grinding floor was exposed to iron oxide dust at an 8 hour time weighted average of 15.65 milligrams per cubic meter (mg/m3), approximately 1.57 times the limit of 10 mg/m3; this limit is established to prevent irritation of the eyes, skin, respiratory system, cough; metal fume fever; siderosis; and iron staining of the eyes. The sample was collected on October 11th, 2011 during a 442 minute sampling period; exposure calculations include a zero increment for the 38 minutes not sampled. (b) The grinder working on the heavy grinding floor was exposed to iron oxide dust at an 8 hour time weighted average of 16.69 mg/m3, approximately 1.67 times the limit of 10 mg/m3; this limit is established to prevent irritation of the eyes, skin, respiratory system, cough; metal fume fever; siderosis; and iron staining of the eyes. The sample was collected on October 11th, 2011 during a 445 minute sampling period; exposure calculations include a zero increment for the 35 minutes not sampled. Abatement normally will be multi-step as follows: STEP 1: Effective respiratory protection shall be provided and used for exposed employees as an interim protective measure until feasible engineering and/or administrative controls can be implemented, or whenever such controls fail to reduce employee exposure to within permissible exposure limits. STEP 1 abatement date is 1 day: ________________________________ STEP 2: Submit to the Area Director a written, detailed plan of abatement outlining a schedule for the implementation of engineering and/or administrative measures to control employee exposure to hazardous substances as referenced in this citation. This plan shall include, at a minimum, target dates for the following actions which must be consistant with the abatement dates required by this citation. 1. Evaluation of engineering/administrative control options; 2. Selection of optimum control methods and completion of design; 3. Procurement, installation, and operation of selected control measures; and 4. Testing and acceptable or midification/redesign of controls. All proposed control measures shall be apporoved for each particular use by a competent industrial hygienist or other technically qualified person. Thirty (30) day progress report is required during the abatement period. STEP 2 abatement date is 30 days: _______________________ STEP 3: Abatement shall have been completed by the implementation of feasible engineering and/or administrative controls upon verification of their effectiveness in achieving compliance. STEP 3 abatement date is 45 days: _______________________
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 H02 I
- Issued
- Jan 10, 2012
- Abate by
- Jan 20, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i): All respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals. A supplied air welding helmet was stored on top of a ventilation hood by the arc welding station in the heat treat building.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Richland Center Foundry
View Richland Center Foundry's full OSHA safety record →
More inspections in this industry (NAICS 331511)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330978602.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.