AKRON, OH —
OSHA Inspection: SUMMIT EQUIPMENT AND SUPPLIES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SUMMIT EQUIPMENT AND SUPPLIES, INC. in 1190 HOME AVENUE, AKRON, OH 44310 (NAICS 423830). OSHA activity number 330979667.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUMMIT EQUIPMENT AND SUPPLIES, INC.
- Site address
- 1190 HOME AVENUE
- City
- AKRON
- State
- OH
- ZIP
- 44310
- Mailing
- 1190 HOME AVENUE, AKRON, OH 44310
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423830
- Employees
- 6
- Ownership type
- A
Citations
26 citations on file for this inspection.
1910.22 A01
- Issued
- Feb 6, 2012
- Abate by
- Mar 7, 2012
- Penalty
- Initial $1,800 · Current $720 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: On or about August 25, 2011, the aisleways, passageways, and rooms were not kept in a clean and orderly fashion, creating trip and fall hazards and obstructions for powered industrial trucks.
Recent events (2)
- — I (S) $720
- — Z (S) $1800
1910.178 L01 I
- Issued
- Feb 6, 2012
- Abate by
- Feb 27, 2012
- Penalty
- Initial $3,600 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about August 25, 2011, employees operating powered industrial trucks were not provided with operator training.
Recent events (2)
- — I (S) $1440
- — Z (S) $3600
1910.184 I09
- Issued
- Feb 6, 2012
- Abate by
- Feb 9, 2012
- Penalty
- Initial $2,400 · Current $960 Reduced
General-duty citation text
29 CFR 1910.184(i)(9): Synthetic web slings with snags, punctures, tears, or cuts were not immediately removed from service if any of the following conditions are present: On or about August 25, 2011, the employer did not remove damaged web slings, used to move steel, from service.
Recent events (2)
- — I (S) $960
- — Z (S) $2400
1910.212 A01
- Issued
- Feb 6, 2012
- Abate by
- Feb 20, 2012
- Penalty
- Initial $4,200 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. The Kasto horizontal band saw was unguarded and 17-inches of the blade were exposed; and b. The Peerless horizontal band saw was unguarded and 13-inches of the blade were exposed.
Recent events (2)
- — I (S) $1680
- — Z (S) $4200
1910.219 E03 I
- Issued
- Feb 6, 2012
- Abate by
- Feb 20, 2012
- Penalty
- Initial $2,400 · Current $960 Reduced
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): On or about August 25, 2011, the vertical belts on the Peerless horizontal band saw were unguarded.
Recent events (2)
- — I (S) $960
- — Z (S) $2400
1910.303 B02
- Issued
- Feb 6, 2012
- Abate by
- Feb 13, 2012
- Penalty
- Initial $1,800 · Current $720 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about August 25, 2011, there were outlet boxes not of solid construction attached to flexible cords throughout the facility.
Recent events (2)
- — I (S) $720
- — Z (S) $1800
1910.1200 E01
- Issued
- Feb 6, 2012
- Abate by
- Feb 27, 2012
- Penalty
- Initial $2,400 · Current $960 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about August 25, 2011, the employer did not have a written hazard communication program and employees were exposed to chemicals such as, but not limited to liquefied petroleum gas and general lubricants.
Recent events (2)
- — I (S) $960
- — Z (S) $2400
1910.1200 G01
- Issued
- Feb 6, 2012
- Abate by
- Feb 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical which they used: On or about August 25, 2011, the employer did not maintain material safety data sheets for all the hazardous chemicals in the workplace, such as, but not limited to liquefied petroleum gas and general lubricants.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Feb 6, 2012
- Abate by
- Feb 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: On or about August 25, 2011, the employer did not provide hazard communication training to employees exposed to chemicals such as, but not limited to liquefied petroleum gas and general lubricants.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.110 E04 III
- Issued
- Feb 6, 2012
- Abate by
- Feb 13, 2012
- Penalty
- Initial $3,600 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.110(e)(4)(iii): Permanent and removable fuel containers were not securely mounted to prevent jarring loose, slipping, or rotating: On or about August 25, 2011, the liquefied petroleum gas tank hasps were broken on the Caterpillar powered industrial truck T80C 41L731 and the tank was not secured properly.
Recent events (2)
- — I (S) $1440
- — Z (S) $3600
1910.110 F02 I
- Issued
- Feb 6, 2012
- Abate by
- Feb 9, 2012
- Penalty
- Initial $3,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.110(f)(2)(i): Containers in storage were not located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons: On or about August 25, 2011, a liquefied petroleum gas cylinder was stored behind the Caterpillar powered industrial truck T80C 41L731.
Recent events (2)
- — I (S) $0
- — Z (S) $3600
1910.157 E03
- Issued
- Feb 6, 2012
- Abate by
- Feb 13, 2012
- Penalty
- Initial $2,400 · Current $960 Reduced
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: On or about August 25, 2011, portable fire extinguishers were not inspected annually. The fire extinguisher by the plasma cutter has not been inspected since December 2005. Note: Applies to any extinguishers provided in the workplace. Maintenance check includes an internal examination, except extinguishers with stored pressure.
Recent events (2)
- — I (S) $960
- — Z (S) $2400
1910.157 G02
- Issued
- Feb 6, 2012
- Abate by
- Feb 20, 2012
- Penalty
- Initial $2,400 · Current $0 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: On or about August 25, 2011, although portable fire extinguishers were available for use, employees were not trained initially or annually thereafter. Note: Applies where all employees are expected to fight fires.
Recent events (2)
- — I (S) $0
- — Z (S) $2400
1910.178 P01
- Issued
- Feb 6, 2012
- Abate by
- Feb 13, 2012
- Penalty
- Initial $3,600 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Where powered industrial trucks were found to be in need of repair, defective, or in any way unsafe, the trucks were not taken out of service until they had been restored to safe operating condition: On or about August 25, 2011, the Caterpillar powered industrial truck T80C 41L731 had a crack in the fork and weak brakes and was not removed from service.
Recent events (2)
- — I (S) $1440
- — Z (S) $3600
1910.178 Q07
- Issued
- Feb 6, 2012
- Abate by
- Feb 13, 2012
- Penalty
- Initial $3,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: On or about August 25, 2011, the Caterpillar powered industrial truck T80C was not inspected at least daily. The powered industrial truck had a crack in the fork, weak brakes, and broken tank hasps.
Recent events (2)
- — I (S) $0
- — Z (S) $3600
1910.305 A02 X
- Issued
- Feb 6, 2012
- Abate by
- Feb 13, 2012
- Penalty
- Initial $1,800 · Current $720 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points: On or about August 25, 2011, a flexible cord was run through the doorway of the bathroom.
Recent events (2)
- — I (S) $720
- — Z (S) $1800
1910.305 A02 XI
- Issued
- Feb 6, 2012
- Abate by
- Feb 20, 2012
- Penalty
- Initial $1,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(xi): Cable assemblies and flexible cords and cables were not supported in place at intervals that ensure that they will be protected from physical damage: On or about August 25, 2011, flexible cords were not supported. a. The yellow flexible cord run through the doorway was not supported. b. The white flexible cord in the breakroom was not supported. NOTE: Support shall be in the form of staples, cables ties, straps, or similar type fittings installed so as not to cause damage.
Recent events (2)
- — I (S) $0
- — Z (S) $1800
1910.305 B01 I
- Issued
- Feb 6, 2012
- Abate by
- Feb 13, 2012
- Penalty
- Initial $1,800 · Current $1,080 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering boxes, cabinets, or fittings were not protected from abrasions: a. On or about August 25, 2011, there was exposed electrical wiring between the electrical disconnect and switch box at the Peerless horizontal band saw that was not protected against abrasion. b. On or about August 25, 2011, there was exposed electrical wiring between electrical disconnects for the plasma cutter that was not protected against abrasion.
Recent events (2)
- — I (S) $1080
- — Z (S) $1800
1910.305 B01 II
- Issued
- Feb 6, 2012
- Abate by
- Feb 13, 2012
- Penalty
- Initial $1,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about August 25, 2011, there were open, unused knockouts in the electrical disconnects for the plasma cutter.
Recent events (2)
- — I (S) $0
- — Z (S) $1800
1910.305 B02 I
- Issued
- Feb 6, 2012
- Abate by
- Feb 13, 2012
- Penalty
- Initial $1,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose: On or about August 25, 2011, there was an outlet box attached to a flexible cord near the plasma cutter that was missing a cover.
Recent events (2)
- — I (S) $0
- — Z (S) $1800
1910.305 E02
- Issued
- Feb 6, 2012
- Abate by
- Feb 13, 2012
- Penalty
- Initial $3,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.305(e)(2): Switches, circuit breakers and switchboards installed in wet locations were not enclosed in weatherproof enclosures: On or about August 25, 2011, the switch box on Peerless horizontal band saw was not enclosed and was sitting in water.
Recent events (2)
- — I (S) $1200
- — Z (S) $3000
1910.305 J01 IV
- Issued
- Feb 6, 2012
- Abate by
- Mar 7, 2012
- Penalty
- Initial $3,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(j)(1)(iv): Fixtures installed in wet or damp locations were not approved for the purpose and were not so constructed or installed that water could not enter or accumulate in wireways, lamp holders or other electrical parts: On or about August 25, 2011, the roof was leaking and overhead lighting installed in these wet locations was not constructed such that water would not enter.
Recent events (2)
- — I (S) $0
- — Z (S) $3000
1910.305 G02 II
- Issued
- Feb 6, 2012
- Abate by
- Feb 13, 2012
- Penalty
- Initial $1,800 · Current $720 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used in continuous lengths without splice or tap: On or about August 25, 2011, flexible cords were not used in continuous lengths. a. The flexible cord from the hot water tank was spliced. b. The yellow flexible cord run through the doorway was spliced. c. The flexible cord for the portable light clamped to the gray cabinet was spliced.
Recent events (2)
- — I (S) $720
- — Z (S) $1800
1910.305 G02 III
- Issued
- Feb 6, 2012
- Abate by
- Feb 13, 2012
- Penalty
- Initial $1,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: On or about August 25, 2011, the flexible cord on pedestal fan near the sales desk did not have adequate strain relief provided.
Recent events (2)
- — I (S) $0
- — Z (S) $1800
1910.132 D02
- Issued
- Feb 6, 2012
- Abate by
- Feb 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment had been performed through written certification that identified the workplace evaluated; the person certifying that the evaluation had been performed; the date(s) of the hazard assessment; and, identified the document as a certification of the hazard assessment: On or about August 25, 2011, the employer did not have a written certification of hazard assessment. Employees were exposed to lacerations and flying particles when cutting, grinding, and handling steel.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.141 D01
- Issued
- Feb 6, 2012
- Abate by
- Feb 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.141(d)(1): Washing facilities were not maintained in a sanitary condition: On or about August 25, 2011, the sinks, toilets, and urinals were unsanitary.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 423830)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330979667.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.