APPLETON, WI ·
OSHA Inspection: PROGRESSIVE CONVERTING INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PROGRESSIVE CONVERTING INC. in 2430 E. GLENDALE AVENUE, APPLETON, WI 54911 (NAICS 322299). OSHA activity number 330980020.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PROGRESSIVE CONVERTING INC.
- Site address
- 2430 E. GLENDALE AVENUE
- City
- APPLETON
- State
- WI
- ZIP
- 54911
- Mailing
- 2430 E. GLENDALE AVENUE, APPLETON, WI 54911
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322299
- Employees
- 100
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.26 C01
- Issued
- Dec 19, 2011
- Abate by
- Jan 18, 2012
- Penalty
- Initial $3,400 · Current $1,600 Reduced
General-duty citation text
29 CFR 1910.26(c)(1): Good safe practices in the use and care of ladder equipment were not employed by the users to get maximum serviceability, safety, and to eliminate unnecessary damage of equipment: a) Four step portable ladder with bent legs near large Maxon sheeter #4. b) Six step portable metal ladder with bent braces near Maxon #1. c) Four step portable metal ladder with bent legs near Maxon #1. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- · I (S) $1600
- · Z (S) $3400
1910.212 A01
- Issued
- Dec 19, 2011
- Abate by
- Apr 1, 2012
- Penalty
- Initial $5,000 · Current $2,900 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Large Maxon sheeter #4 had the guard microswitch altered so the machine could be run with the guard open. b) Maxon sheeter #4 transfer belts had in-running nip points as close as 5" to the frame of the machine. c) Maxon sheeter #4 had open access to transfer belts at the floor level from an opening approximately 70" by 84". d) Maxon #1 had an exposed in-running nip roll approximately 14" from the frame of the machine. e) Maxon #1 had exposed in-running nip points on transfer belts approximately 14" from the frame of the machine. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED.
Recent events (2)
- · I (S) $2900
- · Z (S) $5000
1910.212 A03 II
- Issued
- Dec 19, 2011
- Abate by
- Apr 1, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Galbreath Baler #2 operated with the guard open. b) Maxon #1 approximately 7" high opening to knife roll across width of machine. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.219 D01
- Issued
- Dec 19, 2011
- Abate by
- Jan 18, 2012
- Penalty
- Initial $3,400 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Maxon #1 main drive unit had an exposed belt and pulley at floor level. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- · I (S) $0
- · Z (S) $3400
1910.219 E03 I
- Issued
- Dec 19, 2011
- Abate by
- Jan 18, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): a) Maxon #1 sheeter main drive unit had exposed belt and pulley drive unit. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Progressive Converting INC.
View Progressive Converting INC.'s full OSHA safety record →