Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: SCI FRAMERS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SCI FRAMERS, INC. in 323 WEST BLEEKER STREET, ASPEN, CO 81611 (NAICS 238130). OSHA activity number 330980350.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch SCI Framers, INC. for free Get an email when a new federal OSHA severe-injury report for SCI Framers, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SCI FRAMERS, INC.
Site address
323 WEST BLEEKER STREET
City
ASPEN
State
CO
ZIP
81611
Mailing
P.O. BOX 678, SNOWMASS, CO 81654
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
7
Ownership type
A

8 citations on file for this inspection.

1926.1051 A

Serious Gravity 5 2 instances 6 exposed
Issued
Jan 18, 2012
Abate by
Feb 2, 2012
Penalty
Initial $1,836 · Current $918 Reduced
29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided:    (a)	SCI Framers, Inc.,  @ 323 West Bleeker Street., Aspen, Colorado: On or before August 19, 2011, the employees were required to climb over a concrete wall 30 inches high at the main floor level to gain access to the extension ladder to reach the top floor of the house under construction. This condition exposed employees to the hazard of falling when ascending or descending an unsafe and high point of access.
Recent events (2)
  • · I (S) $918
  • · Z (S) $1836

1926.651 L

Serious Gravity 5 3 instances 6 exposed
Issued
Jan 18, 2012
Abate by
Feb 2, 2012
Penalty
Initial $2,295 · Current $1,147 Reduced
29 CFR 1926.651(l):  Where employees or equipment were required or permitted to cross over excavations, the employer did not provide guardrails systems where walkways were 6 feet or more above lower levels to safe guard employee from fall hazards:    (a)	SCI Framers, Inc., @ 323 West Bleeker Street, Aspen, CO.  On or before August 19, 2011, the employer did not ensure that guardrails systems were provided where employees were required or permitted to cross over excavations walkways.  The employees had been gaining access to the house under construction by using single planking walkways without guardrails installed. This condition exposed the employees to a fall hazard up to 11 feet platform to ground.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $1147
  • · Z (S) $2295

1926.501 B13

Serious Gravity 5 4 instances 6 exposed
Issued
Jan 18, 2012
Abate by
Feb 2, 2012
Penalty
Initial $2,295 · Current $1,148 Reduced
29 CFR 1926.501(b)(13):  Each employee engaged in residential construction activities 6 feet (1.8m) or more above lower levels was not protected by guardrails systems, safety net  system, personal fall arrest system (PFAS), or other approved alternative fall protection systems:    (a)	SCI Framers, Inc.,  @ 323 West Bleeker Street., Aspen, Colorado: On or before August 19, 2011, the exposing employer did not ensure that fall protection systems were provided  while employees were engaged in residential construction activities 6 feet or more above lower levels. iEmployees had been performing activities in all levels of the house under construction where open-sided floor(s) and unprotected window opening(s) had not been provided with guardrails systems to safeguard employees from falling from elevation. This condition exposed the employees to a fall hazard up to approximately 20 feet floor to ground.
Recent events (2)
  • · I (S) $1148
  • · Z (S) $2295

1926.451 F03

Serious Gravity 5 2 instances 6 exposed
Issued
Jan 18, 2012
Abate by
Feb 2, 2012
Penalty
Initial $2,295 · Current $1,147 Reduced
29 CFR 1926.451(f)(3):  Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:    (a)	SCI Framers, Inc., @ 323 West Bleeker Street., Aspen, Colorado: On or before August 19, 2011, the exposing employer did not ensure each fabricated frame mobile scaffold used by employees performing framing activities had been inspected for visible defects and deemed safe to be used by a competent person knowledgeable on scaffold safety. The mobile scaffold had the following deficiencies:    casters were not securely locked in place ,  the caster locking pin was missing,  the top working platforms were not fully planked and lacked guardrails systems,   a cross and diagonal bracing was missing, and  the scaffold was not provided with proper ladder access.     An inspection shall be conducted before allowing employees to use the scaffold.  Without the competent person inspections employees were exposed to scaffold fall hazards of approximately 13 feet.     Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").    Abatement Note:  Concerning the requirements and duties of a competent person:    (1)  "Competent person" means one who is capable of identifying existing and predictable hazards in the surroundings or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them.    (2)  The competent person must be able to carry out the tasks specified in the standard. In order to be able to carry out the tasks the competent person needs to have knowledge in the issues relating to the strength and structural integrity of the scaffold. A competent person must be fully knowledgeable about erecting, disassembling, moving, operating,  Repairing, maintaining and inspecting the scaffold.    (3)  Section 1926.454 states that a competent person will train employees involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold. To meet this requirement, a competent person must be fully knowledgeable about erecting, disassembling, moving, operating, repairing, maintaining and inspecting   the scaffold.
Recent events (2)
  • · I (S) $1147
  • · Z (S) $2295

1926.405 A02 II A

Serious Gravity 5 3 instances 6 exposed
Issued
Jan 18, 2012
Abate by
Feb 2, 2012
Penalty
Initial $1,836 · Current $918 Reduced
29 CFR 1926.405(a)(2)(ii)(A):   Flexible cords and cables used for temporary wiring, which were subject to physical damage, were not protected:    (a)	SCI Framers, Inc., @ 323 West Bleeker Street., Aspen, Colorado: On or before August 19, 2011, the exposing employer did not ensure that the 120-volt, electrical extension cords, which were strung across a gravel roadway were protected from vehicular and construction equipment running over them.  This condition exposed the employees to an electrical hazard.
Recent events (2)
  • · I (S) $918
  • · Z (S) $1836

1926.404 F06

Serious Gravity 5 3 instances 5 exposed
Issued
Jan 18, 2012
Abate by
Feb 2, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    (a)	SCI Framers, Inc., @ 323 West Bleeker Street, Aspen, CO.  On or before August 19, 2011, the employer did not ensure that each 120-volt electrical extension cord used to power electrical tools was equipped with a ground prong.  A missing ground prong on the cord prevented from conducting GFCI testing to assure personnel protection from electrical shock. This condition exposed the employees to an electrical shock.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.403 B01 I

Serious Gravity 5 2 instances 6 exposed
Issued
Jan 18, 2012
Abate by
Feb 2, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(1)(i):  Listed, labeled, or certified electrical equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification of that identified purpose:    (a)	SCI Framers, Inc., @ 323 West Bleeker Street., Aspen, Colorado: On or before August 19, 2011, the exposing employer did not ensure that the 120-volt relocatable tap, which was being used to in the construction site to power such as, but not limited to skill saw, drills, was used in accordance with the instructions included in the listing and labeling, or certification of that identified and intended equipment purpose and/or location.  This condition exposed employees to an electrical hazard.    Abatement Note: Relocatable power taps are not intended to be used in construction sites purposes.  These taps are primarily intended for indoor use as relocatable multiple outlet extensions of a branch circuit to supply laboratory equipment, home workshops, computers, audio and video equipment, and other such equipment, etc.    (b)	SCI Framers, Inc., @ 323 West Bleeker Street., Aspen, Colorado: On or before August 19, 2011, the exposing employer did not ensure that the120-volt metal duplex receptacle box, which was being used to power extension cords running power tools such as, but not limited to skill saw, drills, etc. was used in accordance with the instructions included in the listing and labeling, or certification of that identified and intended equipment purpose and/or location.  Additionally, the receptacle box was missing the cover plate. This condition exposed employees to an electrical hazard.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.20 B02

Serious Gravity 5 4 instances 6 exposed
Issued
Jan 18, 2012
Abate by
Feb 2, 2012
Penalty
Initial $2,295 · Current $0 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of the jobsite, materials, and equipment to be made by a competent person:     (a)	SCI Framers, Inc., @ 323 West Bleeker Street, Aspen, CO.  On or before August 19, 2011, the employer did not ensure that a competent person conducted an inspection(s) of the jobsite to ensure that a fall protection systems was utilized by employees to protect them from fall hazards.  As part of injury/accident prevention responsibilities, the employer did not follow its safety program to ensure employees use fall protection systems while conducting activities in all levels of the house under construction where open-sided floor(s) and unprotected window opening(s) had not been provided with guardrails systems or other suitable system to safeguard employees from falling from elevation 6 feet or more to a lower level. This condition exposed the employees to a fall hazard up to approximately 20 feet floor to ground.    Abatement note: The requirements and duties of a competent person are:    (1)	A competent person as one who is capable of identifying existing and predictable hazards in the surroundings or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has the authority to take prompt corrective measures to eliminate them.    (2)	The competent person must understand and be able to carry out the tasks specified in the OSHA standard.  The competent person must have knowledge about fall protection systems or plans, and the safety program.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $0
  • · Z (S) $2295

View SCI Framers, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330980350.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.