On , OSHA opened a planned safety inspection of DANIEL RODRIGUEZ DBA DANIEL RODRIGUEZ in 15 WISNER, PARK RIDGE, IL 60068 (NAICS 238160). OSHA activity number 330980657.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Daniel Rodriguez DBA Daniel Rodriguez — free Get an email when a new federal OSHA severe-injury report for Daniel Rodriguez DBA Daniel Rodriguez is published. One employer, no account, unsubscribe in one click.
Site address
15 WISNER
City
PARK RIDGE
State
IL
ZIP
60068
Mailing
343 ARGUILLA, GLENWOOD, IL 60425
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

6 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 exposed
Issued
Jan 18, 2012
Abate by
Mar 1, 2012
Penalty
Initial $600 · Current $300 Reduced
29 CFR 1903.19(c)(1):     The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:    Daniel Rodriguez dba Daniel Rodriguez failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:    Citation Number 		Item Number			Abatement Date  01			01				11/9/2011  01			02				11/9/2011  01			03				11/9/2011  01			04a				11/9/2011  01			04b				11/9/2011      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $300
  • — Z (O) $600

1926.300 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 8, 2011
Abate by
Nov 9, 2011
Penalty
Initial $2,400 · Current $2,400
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:    a) A DeWalt angle grinder was not equipped with a blade guard when provided for employee use to cut roof tile.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2400

1926.451 B05 II

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 8, 2011
Abate by
Nov 9, 2011
Penalty
Initial $3,000 · Current $3,000
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end.    a) The work platform of the ladder jack scaffolding from which employees worked extended approxiimately 3 feet over the scaffolds end supports.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $3000

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 8, 2011
Abate by
Nov 9, 2011
Penalty
Initial $4,200 · Current $4,200
29 CFR 1926.451(e)(1): Safe access was not provided to scaffold platforms when the platforms were more than 2 feet (0.6 m) above or below the point of access:    a) Employees were not provided with safe access to scaffolding from which they were required to work at an elevation of approximately 16 feet.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $4200

1926.451 G01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 8, 2011
Abate by
Nov 9, 2011
Penalty
Initial $4,200 · Current $4,200
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:    a) Employees were exposed to the hazard of falling approximately 16 feet while working from ladder jack scaffolding without the benefit of fall protection.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $4200

1926.501 B13

Serious Gravity 10 2 instances 2 exposed
Issued
Nov 8, 2011
Abate by
Nov 9, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor  did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:    a) Employees were not protected from the hazard of falling while performing roofing work on a roof having a pitch of 12/12 and a ground to eave height of approximately 20 feet.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

View Daniel Rodriguez DBA Daniel Rodriguez's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330980657.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.