THORNTON, CO ·
OSHA Inspection: AGUILAR, GUILLERMO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AGUILAR, GUILLERMO in 14189 ST. PAUL STREET, THORNTON, CO 80602 (NAICS 238130). OSHA activity number 330981093.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AGUILAR, GUILLERMO
- Site address
- 14189 ST. PAUL STREET
- City
- THORNTON
- State
- CO
- ZIP
- 80602
- Mailing
- 11145 EAST ALAMEDA AVE APT #103, AURORA, CO 80012
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1926.102 A01
- Issued
- Aug 30, 2011
- Penalty
- Initial $1,301 · Current $1,301
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. a) Aquilar, Guillermo at 14189 St. Paul Street, Denver, CO 80238: On or before August 27, 2011, the employer did not ensure that employees wore safety glasses when using or working in the vicinity of pneumatic nail guns. Condition exposed employees to the hazard of projectiles to the eyes. Abatement note: Abatement certification is not required for this item (see enclosed, "Certification of Corrective Action Worksheet").
Recent events (2)
- · I (S) $1300.5
- · Z (S) $1300.5
1926.501 B13
- Issued
- Aug 30, 2011
- Abate by
- Sep 14, 2011
- Penalty
- Initial $1,530 · Current $1,530
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet(1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems: a) Aquilar, Guillermo at 14189 St. Paul Street, Denver, CO 80238: On or before August 27, 2011, the employer did not ensure that employees were using fall protection when framing this residence in the following instances: 1) The employees were framing on the main floor and did not guard the basement stairway hole measuring 8' x 9' with a 10' fall hazard; and 2) Three basement window wells on the south side, each measuring 3' x 4' with a 5'8" fall hazard, were not guarded. Abatement note: Abatement certification is required for this item (See enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- · I (S) $1530
- · Z (S) $1530
1926.404 A02
- Issued
- Aug 30, 2011
- Abate by
- Sep 9, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(a)(2): A grounded conductor was attached to a terminal or lead so as to reverse designated polarity: a) Aquilar, Guillermo at 14189 St. Paul Street, Denver, CO 80238: On or before August 27, 2011, the employer provided an extension cord with reversed polarity for use with a Skilsaw, model HD77 serial number HD81779. Condition exposed employees to electrical shock hazards. Abatement note: Abatement certification is required for this item (see enclosed, "Certification of Corrective Action Worksheet").
Recent events (2)
- · I (O) $0
- · Z (O) $0
1926.404 F06
- Issued
- Aug 30, 2011
- Abate by
- Sep 14, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:\r\n\r\na) Aquilar, Guillermo at 14189 St. Paul Street, Denver, CO 80238: On or before August 27, 2011, the employer did not ensure that the path to ground was permanent and continuous for the Skilsaw, model HD77 serial number HD81779 that was missing its ground plug. Condition exposed employees to electrical shock hazards.\r\n\r\nAbatement note: Abatement certification is required for this item (see enclosed, \\\"Certification of Corrective Action Worksheet\\\").\r\n
Recent events (2)
- · I (O) $0
- · Z (O) $0
1926.416 E01
- Issued
- Aug 30, 2011
- Abate by
- Sep 9, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:\r\n\r\na) Aquilar, Guillermo at 14189 St. Paul Street, Denver, CO 80238: On or before August 27, 2011, the employer allowed the use of a worn and frayed extension cord to power a Skilsaw, model HD77 serial number HD81779. The skilsaw was not grounded, but was on a working ground fault circuit interrupter. Condition exposed employees to electrical shock hazards.\r\n\r\nAbatement note: Abatement certification is required for this item (see enclosed, \\\\\\\"Certification of Corrective Action Worksheet\\\\\\\").
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Aguilar, Guillermo
View Aguilar, Guillermo's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 330981093.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.