Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: ARTEAGA RENOVATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ARTEAGA RENOVATION in 11620 CHESTER RD, CINCINNATI, OH 45232 (NAICS 236116). OSHA activity number 330981101.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Arteaga Renovation for free Get an email when a new federal OSHA severe-injury report for Arteaga Renovation is published. One employer, no account, unsubscribe in one click.
Establishment
ARTEAGA RENOVATION
Site address
11620 CHESTER RD
City
CINCINNATI
State
OH
ZIP
45232
Mailing
6207 PINTAIL CT, LOVELAND, OH 45140
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
3
Ownership type
Private (A)

3 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 5, 2011
Abate by
Oct 6, 2011
Penalty
Initial $3,600 · Current $1,800 Reduced
29 CFR 1926.451(b)(1):     Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)  a) Located along the side or end of the hotel structure there was an employee observed working from a mobile self-supported tubular welded frame scaffolding system which was not folly planked in that the end frame platform was decked with only one 19" wide pic leaving an approximate 39" area unprotected exposing the employee to a fall potential in excess of 7'.
Recent events (2)
  • · I (S) $1800
  • · Z (S) $3600

1926.451 F07

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 5, 2011
Abate by
Oct 11, 2011
Penalty
Initial $3,600 · Current $0 Reduced
29 CFR 1926.451(f)(7):     Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.  a) Located along the side or end of the hotel structure mobile self-supported tubular welded frame scaffolding was not erected and used properly in that a competent person did not supervise the erection or alteration process to ensure fully planked work surfaces or guardrail systems were erected or utilized.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3600

1926.501 B06

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 5, 2011
Abate by
Oct 6, 2011
Penalty
Initial $3,600 · Current $1,800 Reduced
29 CFR 1926.501(b)(6):     Each employee on ramps, runways, and other walkways was not protected from falling 6 feet (1.8 m) or more to lower levels by guardrail systems:  a) Located along the front and side or end of the hotel structure employees were observed working from walkways with unprotected sides or edges not protected by standard guardrails or equivalent exposing employees to fall potentials in excess of 8'.