GRAND JUNCTION, CO —
OSHA Inspection: BEST PRICED STUCCO
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BEST PRICED STUCCO in 459 NORTH AVE., GRAND JUNCTION, CO 81501 (NAICS 238140). OSHA activity number 330981473.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BEST PRICED STUCCO
- Site address
- 459 NORTH AVE.
- City
- GRAND JUNCTION
- State
- CO
- ZIP
- 81501
- Mailing
- 424 CLIFTON RD. #167, CLIFTON, CO 81520
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 7
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B10
- Issued
- Oct 13, 2011
- Abate by
- Nov 12, 2011
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1926.451(b)(10): Scaffold components manufactured by different manufacturers were intermixed such that the components fit together with force and the scaffold's structural integrity was not maintained by the user: (a) Best Priced Stucco at 459 North Ave. in Grand Junction, CO: On and before August 26, 2011 scaffold components of different manufacturers were intermixed such that the components fit together with force and the scaffold's integrity was not maintained. A fabricated frame scaffold, two frames high, was erected to install stucco on a dental office building. The second tier of the scaffold was comprised of non-standard posts instead of frames. On 8/30/11, the scaffold was comprised of components from at least three manufacturers. This condition exposed employees to a fall hazard of approximately 16 feet. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $2400
1926.451 F03
- Issued
- Oct 13, 2011
- Abate by
- Nov 12, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: (a) Best Priced Stucco at 459 North Ave. in Grand Junction, CO: On and before August 26, 2011 the employer did not ensure the fabricated frame scaffold had been inspected for visible defects by a competent person before use. Without the inspections employees were exposed to scaffold fall hazards of approximately 16 feet. Abatement Note: Concerning the requirements and duties of a competent person: (1) "Competent person" means one who is capable of identifying existing and predictable hazards in the surroundings or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them. (2) The competent person must be able to carry out the tasks specified in the standard. In order to be able to carry out the tasks the competent person needs to have knowledge in the issues relating to the strength and structural integrity of the scaffold. A competent person must be fully knowledgeable about erecting, disassembling, moving, operating, repairing, maintaining and inspecting the scaffold. (3) Section 1926.454 states that a competent person will train employees involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold. To meet this requirement, a competent person must be fully knowledgeable about erecting, disassembling, moving, operating, repairing, maintaining and inspecting the scaffold. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1926.451 G04 I
- Issued
- Oct 13, 2011
- Abate by
- Nov 12, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: a) Best Priced Stucco at 459 North Ave. in Grand Junction, CO: On and before August 26, 2011, the employer did not ensure employees working on a scaffold were protected from falls via the use of guardrails along all open sides and ends of the scaffold. This condition exposed employees to fall hazards of approximately 16 feet. Abatement Note: Crossbracing is acceptable in place of a midrail when the crossing point of two braces is between 20 inches (0.5 m) and 30 inches (0.8 m) above the work platform or as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform. The end points at each upright shall be no more than 48 inches (1.3 m) apart. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
More inspections at Best Priced Stucco
View Best Priced Stucco's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330981473.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.