OSHA Inspection: ELITE CONSTRUCTION DESIGN, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ELITE CONSTRUCTION DESIGN, INC. in 3930 UTICA STREET, DENVER, CO 80212 (NAICS 236118). OSHA activity number 330981713.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Elite Construction Design, INC. — free Get an email when a new federal OSHA severe-injury report for Elite Construction Design, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3930 UTICA STREET
City
DENVER
State
CO
ZIP
80212
Mailing
2300 W. 2ND AVE., DENVER, CO 80223
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
2
Ownership type
A

5 citations on file for this inspection.

1926.404 B01 II

Serious Gravity 1 1 instance 4 exposed
Issued
Sep 1, 2011
Abate by
Sep 12, 2011
Penalty
Initial $1,530 · Current $918 Reduced
29 CFR 1926.404(b)(1)(ii):  On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection:\r\n\r\na)  Elite Construction Design, Inc. at 3930 Utica Street, Denver, CO 80212:  On or before August 27, 2011, the employer did not ensure that the temporary electrical panel included a working GFCI.  Condition exposed employees to electrical shock hazards.\r\n\r\nAbatement note:  Abatement certification is required for this item (see enclosed, \"Certification of Corrective Action Worksheet\").\r\n
Recent events (2)
  • — I (S) $918
  • — Z (S) $1530

1926.404 F06

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 1, 2011
Abate by
Sep 11, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6):  The path to ground from circuits, equipment, or enclosures was not permanent and continuous:\r\n\r\na)  Elite Construction Design, Inc. at 3930 Utica Street, Denver, CO 80212:  On or before August 27, 2011, the employer did not ensure that two 110 volt extensions cords in use were properly grounded.  Condition exposed employees to electrical shock hazards.\r\n\r\nAbatement note:  Abatement certification is required for this item (see enclosed, \"Certification of Corrective Action Worksheet\").\r\n
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 D

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 1, 2011
Abate by
Sep 11, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.405(d):  A panelboard was not dead front:a)  Elite Construction Design, Inc. at 3930 Utica Street, Denver, CO 80212:  On or before August 27, 2011, the employer did not ensure that the temporary electrical panel included a dead front.  Condition exposed employees to electrical shock hazards.Abatement note:  Abatement certification is required for this item (see enclosed, "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.416 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 1, 2011
Abate by
Sep 11, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1):  Worn or frayed electric cords or cables were used: a)  Elite Construction Design, Inc. at 3930 Utica Street, Denver, CO 80212:  On or before August 27, 2011, the employer allowed the use of a worn and frayed 110 volt extension cord.  Condition exposed employees to electrical shock hazards.Abatement note:  Abatement certification is required for this item (see enclosed, \"Certification of Corrective Action Worksheet\").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 1, 2011
Abate by
Sep 16, 2011
Penalty
Initial $1,530 · Current $918 Reduced
29 CFR 1926.451(e)(1):  When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access:a)  Elite Construction Design, Inc. at 3930 Utica Street, Denver, CO 80212:  On or before August 27, 2011, the controlling employer did not ensure that a safe means of access was provided for the masonary fabricated frame saffold.Condition exposed employees to fall hazars of up to 11'.  Abatement note:  Abatement certification is required for this item (see enclosed, "Certification of Corrective Action Worksheet").