UNIONTOWN, OH —
OSHA Inspection: KOVATCH CASTINGS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of KOVATCH CASTINGS in 3743 TABS DRIVE, UNIONTOWN, OH 44685 (NAICS 331512). OSHA activity number 330981960.
Where did this inspection happen?
- Establishment
- KOVATCH CASTINGS
- Site address
- 3743 TABS DRIVE
- City
- UNIONTOWN
- State
- OH
- ZIP
- 44685
- Mailing
- 3743 TABS DRIVE, UNIONTOWN, OH 44685
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331512
- Employees
- 194
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.132 A
- Issued
- Abate by
- Penalty
- Initial $5400.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: Shell Department and Back-Up Coat Area: Hard hats/bump caps were not provided when employees were exposed to the conveyor system which was approximately 5 1/2 feet from floor level. In lieu of hard hats/bump caps, the employer may designate walkways in the areas where employees do not have to go under the conveyor sytem.
Recent events (2)
- — I (O) $0
- — Z (S) $5400
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $3600.00 · Current $3600.00
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: The company did not establish a program to protect employees involved with servicing and maintenance of machines and equipment from the unexpected energizing, start up or release of stored energy. Energy sources included, but are not limited to, electrical, pneumatic, hydraulic, etc. The company maintains and services equipment such as, but not limited to, ovens, robotics, mixers, conveyors, etc.
Recent events (2)
- — I (S) $3600
- — Z (S) $3600
1910.178 A04
- Issued
- Penalty
- Initial $3600.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications or additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: On the Flexi electric forklift, there was a tarp over the top of the cage preventing the operator's visibility.
Recent events (2)
- — I (S) $0
- — Z (S) $3600
1910.178 L01 II
- Issued
- Abate by
- Penalty
- Initial $3600.00 · Current $3600.00
General-duty citation text
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck: On or before 8/30/11, the employer did not do a driving evaluation of the operator's performance in the workplace.
Recent events (2)
- — I (S) $3600
- — Z (S) $3600
1910.178 Q07
- Issued
- Abate by
- Penalty
- Initial $2700.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.178(q)(7): Powered industrial truck(s) which were used on a round-the-clock basis were not examined for defects after each shift: Powered industrial trucks were not inspected per shift. Checks on the trucks was only done on first shift.
Recent events (2)
- — I (S) $0
- — Z (S) $2700
1910.303 B01
- Issued
- Penalty
- Initial $4500.00 · Current $4500.00
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: (a) There was an electric heater inside the water tank that did not have a GFCI. (b) There was an electric heater inside the pattern wash tank, that did not have a GFCI. (c) There was a broken/missing switch by the pattern wash tank.
Recent events (2)
- — I (S) $4500
- — Z (S) $4500
More inspections in this industry (NAICS 331512)
MILWAUKIE, OR—2026-06-18 00:00:00
317744514 - PCC STRUCTURALS INC
BAY CITY, MI—2026-06-16 00:00:00
ACRA CAST INC
WATERTOWN, WI—2026-05-29 00:00:00
METALTEK INTERNATIONAL, INC.
GALLATIN, TN—2026-05-14 00:00:00
PRECISION CASTINGS OF TENNESSEE, INC.
DOUGLASSVILLE, PA—2026-01-15 00:00:00
WOLF TECHNOLOGIES, LLC
More inspections in OH
WELLINGTON, OH—2026-07-16 00:00:00
WHIRLAWAY CORPORATION
WAUSEON, OH—2026-07-16 00:00:00
WATSON WELL DRILLING INC.
SEVEN HILLS, OH—2026-07-15 00:00:00
STONEY ACRES BUILDERS LLC
SEVEN HILLS, OH—2026-07-15 00:00:00
GRB ENTERPRISES LLC
CHILLICOTHE, OH—2026-07-15 00:00:00
KENWORTH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330981960.