OSHA Inspection: ARNIE CHRISTIANSEN MASON CONTRACTOR LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ARNIE CHRISTIANSEN MASON CONTRACTOR LLC in AUTOZONE, SHEBOYGAN, WI 53081 (NAICS 238140). OSHA activity number 330984055.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Arnie Christiansen Mason Contractor LLC — free Get an email when a new federal OSHA severe-injury report for Arnie Christiansen Mason Contractor LLC is published. One employer, no account, unsubscribe in one click.
Site address
AUTOZONE
City
SHEBOYGAN
State
WI
ZIP
53081
Mailing
2304 65TH DR., FRANKSVILLE, WI 53126
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
9
Ownership type
A

6 citations on file for this inspection.

1926.451 B01 I

Other-than-serious 1 instance 6 exposed
Issued
Sep 14, 2011
Abate by
Oct 5, 2011
Penalty
Initial $2,700 · Current $0 Reduced
29 CFR 1926.451(b)(1)(i):     Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary.        The 2X10 scaffold planks on the working level had gaps greater than one inch along the length and width of the scaffold.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2700

1926.451 G04 I

Serious Gravity 5 2 instances 6 exposed
Issued
Sep 14, 2011
Abate by
Oct 5, 2011
Penalty
Initial $0 · Current $1,500
29 CFR 1926.451(g)(4)(i): \r\n\r\nGuardrail systems were not installed along all open sides and ends of platforms.\r\n\r\n\r\nThe ends of the working level were not guarded, and the outside edges were only protected by the cross braces.\r\n\r\n
Recent events (2)
  • — I (S) $1500
  • — Z (S) $0

1926.451 H02 I

Serious Gravity 5 1 instance 6 exposed
Issued
Sep 14, 2011
Abate by
Oct 5, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.451(h)(2)(i): \r\n\r\nThe area below the scaffold was not barricaded, and employees were not prohibited from entering the hazard area.\r\n\r\nNo barricade or warning line was used to prevent EE access under the scaffold.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.706 A05

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 14, 2011
Abate by
Oct 5, 2011
Penalty
Initial $2,700 · Current $1,500 Reduced
29 CFR 1926.706(a)(5):     The limited access zone shall remain in place until the wall is adequately supported to prevent overturning and to prevent collapse unless the height of wall is over eight feet, in which case, the limited access zone shall remain in place until the requirements of paragraph (b) of this section have been met.    A limited access zone was not established or maintained on the interior of the building for the side and back walls being built.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2700

1926.706 B

Serious Gravity 5 3 instances 6 exposed
Issued
Sep 14, 2011
Abate by
Oct 5, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.706(b): \r\n\r\nMasonry walls over eight feet in height were not adequately braced to prevent overturning and to prevent collapse until permanent supporting elements of the structure were in place:\r\n(a)(LOCATIONS)(SPECIFY HEIGHT AND LENGTH OF WALL)(DESCRIBE ANY BRACING BEING USED AND WHY IT WAS NOT ADEQUATE)\r\n\r\nThe inside of the south wall was not braced at all, and the other bracing was placed on approximately 14\' centers and anchored to the class C soil with 3/4\" steel form pins.  The wall was approximately 17\' high and 70\' long.\r\n
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Other-than-serious 1 instance 6 exposed
Issued
Sep 14, 2011
Abate by
Oct 5, 2011
Penalty
Initial $2,700 · Current $0 Reduced
29 CFR 1926.1053(b)(1): \r\n\r\nWhere portable ladders were used for access to an upper landing surface and the ladder\u00E2\u00BF\u00BFs length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:\r\n(a) (LOCATION) (IDENTIFY SPECIFIC OPERATION(S) AND/OR CONDITIONS)\r\n\r\nThe ladder used to access the working level of the scaffold extended 18\" above the deck.\r\n
Recent events (2)
  • — I (O) $0
  • — Z (S) $2700

View Arnie Christiansen Mason Contractor LLC's full OSHA safety record →