Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: THE SEGERDAHL CORP.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of THE SEGERDAHL CORP. in 1351 S. WHEELING ROAD, WHEELING, IL 60090 (NAICS 323110). OSHA activity number 330984113.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Segerdahl Corp. for free Get an email when a new federal OSHA severe-injury report for The Segerdahl Corp. is published. One employer, no account, unsubscribe in one click.
Establishment
THE SEGERDAHL CORP.
Site address
1351 S. WHEELING ROAD
City
WHEELING
State
IL
ZIP
60090
Mailing
1351 S. WHEELING ROAD, WHEELING, IL 60090
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323110
Employees
234
Ownership type
Private (A)

2 citations on file for this inspection.

1910.95 G06

Serious Gravity 10 3 instances 3 exposed
Issued
Nov 7, 2011
Abate by
Nov 15, 2011
Penalty
Initial $7,000 · Current $3,500 Reduced

Hazardous substances 81108111

29 CFR 1910.95(g)(6):     New audiograms were not obtained annually for each employee exposed to noise at or above an 8-hour time-weighted average of 85 dBA.    a) The Segerdahl Corp. did not ensure that all employees exposed to noise at or above an 8-hour time-weighed average (TWA) of 82.1 dBA received a new audiogram annually.  On October 14, 2011, personal noise monitoring was performed to verify employees performing the duty of a second pressman exceeded an 8-hour TWA of 82.1 dBA and were required to be included in the company's hearing conservation program.  There were three second pressman that did not receive an annual audiogram consistently between 2007 and 2009.    Note: The 8-hour TWA sound level of 85 dBA that triggers the requirement for a hearing conservation program (HCP) can be adjusted for work shifts less than or greater than 8 hours.  When making the adjustment, the following formula is used:  AL = 90 = 16.61 Log [50/12.5(hours)].  Affected employees were exposed to continuous noise levels over a 12-hour work shift.  Therefore, the TWA sound level that triggers the requirement for a HCP was adjusted or reduced for the affected employees to 82.1 dBA.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $3500
  • · Z (S) $7000

1910.95 K02

Serious Gravity 10 3 instances 3 exposed
Issued
Nov 7, 2011
Abate by
Nov 15, 2011
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.95(k)(2):     The training program was not repeated annually for each employee included in the hearing conservation program:    a) The Segerdahl Corp. did not ensure that all employees included in the company's hearing conservation program received annual training.  On October 14, 2011, personal noise monitoring was performed to verify the noise exposures of employees performing the duties of first pressman and second pressman exceeded an 8-hour TWA of 82.1 dBA and/or 85 dBA and that they were required to be included in the company's hearing conservation program.  There were two first pressman who did not receive noise training in 2010 and one second pressman who did not received noise training in 2009 or 2010.     Note: The 8-hour TWA sound level of 85 dBA that triggers the requirement for a hearing conservation program (HCP) can be adjusted for work shifts less than or greater than 8 hours.  When making the adjustment, the following formula is used:  AL = 90 = 16.61 Log [50/12.5(hours)].  Affected employees were exposed to continuous noise levels over a 12-hour work shift.  Therefore, the TWA sound level that triggers the requirement for a HCP was adjusted or reduced for the affected employees to 82.1 dBA.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $3500
  • · Z (S) $7000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 330984113.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.