Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: SEVEN-D CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SEVEN-D CONSTRUCTION, INC. in 534 N. WOOD STREET, CHICAGO, IL 60622 (NAICS 237110). OSHA activity number 330984295.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Seven-D Construction, INC. for free Get an email when a new federal OSHA severe-injury report for Seven-D Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
534 N. WOOD STREET
City
CHICAGO
State
IL
ZIP
60622
Mailing
2000 W. 43RD ST., CHICAGO, IL 60609
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
90
Ownership type
A

3 citations on file for this inspection.

1926.200 G02

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 8, 2011
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.200(g)(2): All traffic control signs or devices used for protection of construction workers shall conform to Part VI of the Manual of Uniform Traffic Control Devices (MUTCD"), 1988 Edition, Revision 3, September 3, 1993, FHWA-SA-94-027 or Part VI of the Manual on Uniform Traffic Control Devices, Millennium Edition, December 2000, FHWA, which are incorporated by reference:    On or about September 2, 2011, at the above addressed jobsite, employees were permitted to work in and near the traveled way of south bound Wood Street without providing signage indicating how motor vehicle traffic can move through the temporary traffic control zone as required by MUTCD Section 6G.03.
Recent events (1)
  • · Z (S) $2800

1926.403 B01

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 8, 2011
Penalty
Initial $2,100 · Current $2,100
29 CFR 1926.403(b)(1): Examination. The employer shall ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees:    a.  On or about September 2, 2011, at the above addressed jobsite, employees were exposed to electric shock when working in proximity to a damaged electrical receptacle.
Recent events (1)
  • · Z (S) $2100

1926.652 G02

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 8, 2011
Penalty
Initial $2,100 · Current $2,100
29 CFR 1926.652(g)(2):  Additional requirement for shield systems used in trench excavations. Excavations of earth material to a level not greater than 2 feet (.61 m) below the bottom of a shield shall be permitted, but only if the shield is designed to resist the forces calculated for the full depth of the trench, and there are no indications while the trench is open of a possible loss of soil from behind or below the bottom of the shield:    a.  On or about September 2, 2011, at the above addressed jobsite, employees were installing a sewer in a trench with approximately four (4) feet of earth material under the shield system.  Employees were thereby exposed to the hazards associated with cave-ins.
Recent events (1)
  • · Z (S) $2100

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330984295.