OSHA Inspection: BRUBAKER GRAIN & CHEMICAL, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BRUBAKER GRAIN & CHEMICAL, INC. in 307 W CENTER STREET, FARMERSVILLE, OH 45325 (NAICS 424910). OSHA activity number 330985599.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Brubaker Grain & Chemical, INC. — free Get an email when a new federal OSHA severe-injury report for Brubaker Grain & Chemical, INC. is published. One employer, no account, unsubscribe in one click.
Site address
307 W CENTER STREET
City
FARMERSVILLE
State
OH
ZIP
45325
Mailing
307 WEST CENTER ST., FARMERSVILLE, OH 45325
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424910
Employees
20
Ownership type
A

8 citations on file for this inspection.

1910.219 E03 I

Serious Gravity 5 6 instances 6 exposed
Issued
Oct 4, 2011
Abate by
Oct 26, 2011
Penalty
Initial $2,400 · Current $800 Reduced
29 CFR 1910.219(e)(3)(i):     Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs(m) and (o) of this section.    a) Guarding was not provided on the motor drive belt for the Box fan in the office storage area exposing employees to pinch points.  b) Guarding was not provided on the motor drive belt for the Seed mixer exposing employees to pinch points.  c) Guarding was not provided on the motor drive belt for the Roller Mill exposing employees to pinch points.  d) Guarding was not provided on the motor drive belt for the Big Bagger exposing employees to pinch points.  e) Guarding was not provided on the motor drive belt on the Horse Bagger exposing employees to pinch points.  f)  Guarding was not provided on the motor drive belt on the Molasses tank exposing employees to pinch points.  g) Guarding was not provided on the motor drive belt on the Corn Cleaner exposing employees to pinch points.  h) Guarding was not provided on the motor drive belt on the Hammer Mill exposing employees to pinch points.  i)  Guarding was not provided on the motor drive belt on the Grain side basement expoing employees to pinch points.
Recent events (3)
  • — F (S) $800
  • — C (S) $2400
  • — Z (S) $2400

1910.219 C02 I

Serious Gravity 5 2 instances 3 exposed
Issued
Oct 4, 2011
Penalty
Initial $1,561 · Current $550 Reduced
29 CFR 1910.219(c)(2)(i):     All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform,excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by atrough enclosing sides and top or sides and bottom of shafting as location requires.      a) Feed mixer conveyer shaft was not guarded to prevent employees exposure to rotating parts.  b) Horse bagger conveyer shaft was not guarded to prevent employees exposure to rotating parts.
Recent events (3)
  • — F (S) $550
  • — C (S) $1560.6
  • — Z (S) $1560.6

1910.178 L01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 4, 2011
Penalty
Initial $2,160 · Current $550 Reduced
29 CFR 1910.178(l)(1)(ii):     Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer shall ensure that each operator has successfully completed the training required by this paragraph (l), except as permitted by paragraph (l)(5).    a) The employer did not ensure that the operators of powered industrial vehicle(s)  (forklift) were trained prior to allowing them  to drive a forklift truck.
Recent events (3)
  • — F (S) $550
  • — C (S) $2160
  • — Z (S) $2160

1910.132 A

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 4, 2011
Abate by
Oct 26, 2011
Penalty
Initial $2,160 · Current $800 Reduced
29 CFR 1910.132(a):     'Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.    a) Personal protective equipment was not povided for employees on the grain storage truck to prevent them from falls in excess of eight feet.
Recent events (3)
  • — F (S) $800
  • — C (S) $2160
  • — Z (S) $2160

1910.23 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 4, 2011
Abate by
Nov 17, 2011
Penalty
Initial $2,160 · Current $800 Reduced
29 CFR 1910.23(c)(1):     Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall beguarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toeboard wherever, beneath the open sides,    a) In the main mill mixing area elevated platform was not equipped with a guard railing system to prevent employees to fall  in excesss of eight feet.
Recent events (3)
  • — F (S) $800
  • — C (S) $2160
  • — Z (S) $2160

1910.305 B01 II

Other-than-serious 1 instance 1 exposed
Issued
Oct 4, 2011
Penalty
Initial $1,620 · Current $0 Reduced
29 CFR 1910.305(b)(1)(ii):     Unused openings in cabinets, boxes, and fittings shall be effectively closed.    a) Knockout covers were missing from the main power disconnect box for the outside mixer.
Recent events (3)
  • — F (O) $0
  • — C (S) $1620
  • — Z (S) $1620

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 4, 2011
Abate by
Oct 12, 2011
Penalty
Initial $2,400 · Current $600 Reduced
29 CFR 1910.303(g)(2)(i):     Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidentalcontact by use of approved cabinets or other forms of approved enclosures or by any of the following means:    a) The main breaker panel on the grain side was not covered to prevent contact with live electrical parts.
Recent events (3)
  • — F (S) $600
  • — C (S) $2400
  • — Z (S) $2400

1910.272 G01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 4, 2011
Abate by
Nov 17, 2011
Penalty
Initial $3,000 · Current $0 Reduced
29 CFR 1910.272(g)(1)(ii):     All mechanical, electrical, hydraulic, and pneumatic equipment which presents a danger to employees inside grain storage structures shall be deenergized and shall be disconnected, locked-out and tagged, blocked-off, or otherwise prevented from operating by other equally effective means or methods.      a) Employees were allowed to enter the bin while the sweep was energized exposing them to sweep auger and/or moving parts.
Recent events (3)
  • — F (S) $0
  • — C (S) $3000
  • — Z (S) $3000

View Brubaker Grain & Chemical, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330985599.