DAYTON, OH ·
OSHA Inspection: DAYTON COATING TECHNOLOGIES, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DAYTON COATING TECHNOLOGIES, LLC in 1926 E. SIEBENTHALER AVE., DAYTON, OH 45414 (NAICS 332812). OSHA activity number 330986225.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DAYTON COATING TECHNOLOGIES, LLC
- Site address
- 1926 E. SIEBENTHALER AVE.
- City
- DAYTON
- State
- OH
- ZIP
- 45414
- Mailing
- 1926 E. SIEBENTHALER AVE., DAYTON, OH 45414
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 10
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.215 A04
- Issued
- Sep 19, 2011
- Abate by
- Oct 19, 2011
- Penalty
- Initial $2,040 · Current $1,428 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: (a) In the back storage area, the Central Machinery 8 inch double wheel pedestal grinder (Item #37823 3/4 H.P. 3450 r.p.m.) was used for grinding and deburring with the work rest swung out of the way and not properly adjusted.
Recent events (2)
- · I (S) $1428
- · Z (S) $2040
1910.215 B09
- Issued
- Sep 19, 2011
- Abate by
- Oct 19, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) In the back storage area, the Central Machinery 8 inch double pedestal grinder (Item # 37823, 3/4 H.P., 3450 rpm) was used to grind and debur and the adjustable tongue guard was swung out of the way and not properly adjusted.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 G02 I
- Issued
- Sep 19, 2011
- Abate by
- Oct 19, 2011
- Penalty
- Initial $2,550 · Current $1,785 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): (a) On the Coating Chambers, Machine A and B, there were open boxed on the back side of each machine exposing live 400 v terminal connections for the heater units.
Recent events (2)
- · I (S) $1785
- · Z (S) $2550
More inspections at Dayton Coating Technologies, LLC
View Dayton Coating Technologies, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332812)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 330986225.