Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: AMEN OILFIELD SERVICE, INC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of AMEN OILFIELD SERVICE, INC in 23295 US HWY 85, LA SALLE, CO 80645 (NAICS 213112). OSHA activity number 330989237.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Amen Oilfield Service, INC for free Get an email when a new federal OSHA severe-injury report for Amen Oilfield Service, INC is published. One employer, no account, unsubscribe in one click.
Site address
23295 US HWY 85
City
LA SALLE
State
CO
ZIP
80645
Mailing
24138 WELD CR 38, LA SALLE, CO 80645
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
11
Ownership type
A

5 citations on file for this inspection.

1910.134 I07

Serious Gravity 1 11 exposed
Issued
Oct 13, 2011
Abate by
Oct 28, 2011
Penalty
Initial $1,530 · Current $1,530
29 CFR 1910.134(i)(7): The employer did not ensure that the oil lubricated compressor used to supply breathing air had a high-temperature or carbon monoxide alarm(s) or both:    (a) Amen Oilfield Services, Inc @ 23295 US Hwy 85, La Salle, CO 80645: On and before 9/14/11, the employer did not ensure that the Gast ambient air pump, which was used as part of a supplied air respiratory protection system, was equipped with a high temperature or carbon monoxide alarm. Employees use the supplied air system when entering tanks to conduct pressure cleaning activities. This condition exposed employees to respiratory hazards.
Recent events (1)
  • · Z (S) $1530

1910.134 C01

Other-than-serious 11 exposed
Issued
Oct 13, 2011
Abate by
Oct 28, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1): A written respiratory protection program with worksite specific procedures, as specified in subparagraphs (c)(1)(i) through (ix) of this section, was not established and implemented where respirator(s) were necessary to protect the health of the employee or whenever respirator(s) were required by the employer:      (a) Amen Oilfield Services, Inc @ 23295 US Hwy 85, La Salle, CO 80645: On and before 9/14/11, the employer did not establish and implement a respiratory protection program. Employees wore Survivair full-face, tight-fitting, supplied air respirators prior to entering permit required confined spaces to conduct cleaning activities. This condition exposed employees to respiratory hazards.
Recent events (1)
  • · Z (O) $0

1910.134 E01

Other-than-serious 2 exposed
Issued
Oct 13, 2011
Abate by
Oct 28, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator before the employee was required to use the respirator in the workplace:     (a) Amen Oilfield Services, Inc @ 23295 US Hwy 85, La Salle, CO 80645: On and before 9/14/11, the employer did not ensure that medical evaluations were provided to employees prior to issuance and subsequent use of respirators. The employer provided employees with Survivar full-face, tight-fitting respirators to be used with a Gast ambient air pump during cleaning operations inside confined spaces. This condition exposed employees to respiratory hazards.
Recent events (1)
  • · Z (O) $0

1910.134 F01

Other-than-serious 2 exposed
Issued
Oct 13, 2011
Abate by
Oct 28, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirators were given a qualitative fit test (QLFT) or quantitative fit test (QNFT):    (a) Amen Oilfield Services, Inc @ 23295 US Hwy 85, La Salle, CO 80645: On and before 9/14/11, the employer did not ensure that fit tests were provided to employees prior to the issuance and usage of respirators. The employer provided employees with Survivar full-face, tight-fitting respirators to be used with a Gast ambient air pump during cleaning operations inside confined spaces. This condition exposed employees to respiratory hazards.
Recent events (1)
  • · Z (O) $0

1910.134 K01

Other-than-serious 2 exposed
Issued
Oct 13, 2011
Abate by
Oct 28, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(1): The employer did not provide training prior to requiring employees to use respirators in the workplace:     (a) Amen Oilfield Services, Inc @ 23295 US Hwy 85, La Salle, CO 80645: On and before 9/14/11, the employer did not ensure that respirator training was provided to employees prior to the use of Survivar full-face, tight-fitting supplied air respirators. Employees used respirators during cleaning operations inside confined spaces. This condition exposed employees to respiratory hazards.
Recent events (1)
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330989237.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.