NAMPA, ID —
OSHA Inspection: PRECISION DESIGN & TRIM, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PRECISION DESIGN & TRIM, LLC in 17863 MOUNTAIN SPRINGS AVE, NAMPA, ID 83687 (NAICS 236115). OSHA activity number 331064824.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PRECISION DESIGN & TRIM, LLC
- Site address
- 17863 MOUNTAIN SPRINGS AVE
- City
- NAMPA
- State
- ID
- ZIP
- 83687
- Mailing
- 1168 E. PIENZA ST., MERIDIAN, ID 83642
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.304 I01
- Issued
- Oct 25, 2011
- Abate by
- Nov 16, 2011
- Penalty
- Initial $2,040 · Current $1,020 Reduced
General-duty citation text
29 CFR 1926.304(i)(1): Each circular hand-fed rip saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut: a) Jobsite: On September 14, 2011 and times prior thereto, employees were exposed to possible amputation or laceration while operating a table saw that did not have a guard for the blade. Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $1020
- — Z (S) $2040
1926.405 J01 I
- Issued
- Oct 25, 2011
- Abate by
- Nov 16, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(j)(1)(i): Fixtures, lampholders, lamps, rosettes, or receptacles had live parts normally exposed to employee contact: Jobsite: On September 14, 2011, and times prior thereto, employees were exposed to electric shock from the exposed terminal screws. Note: Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Precision Design & Trim, LLC
View Precision Design & Trim, LLC's full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331064824.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.