Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DAVID HOYT

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DAVID HOYT in 18 BADGER ST., CONCORD, NH 03301 (NAICS 238160). OSHA activity number 331065326.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch David Hoyt — free Get an email when a new federal OSHA severe-injury report for David Hoyt is published. One employer, no account, unsubscribe in one click.
Establishment
DAVID HOYT
Site address
18 BADGER ST.
City
CONCORD
State
NH
ZIP
03301
Mailing
90 UNION RD., NORTHFIELD, NH 03276
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

17 citations on file for this inspection.

1926.21 B02

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 14, 2012
Abate by
Apr 4, 2012
Penalty
Initial $3,000 · Current $1,000 Reduced
29 CFR 1926.21(b)(2):  The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury.    Jobsite:  The employer did not train the employees in the recognition and avoidance of electrical and flying object hazards or the regulations to control or eliminate them.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3000

1926.454 A

Serious Gravity 1 2 instances 2 exposed
Issued
Mar 14, 2012
Abate by
Apr 4, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a):  The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.    Jobsite:  The employees, working from the elevated platforms of the pump-jack and roof bracket scaffolds, were not trained in the recognition of scaffold hazards or the procedures designed to control or eliminate them.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.503 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 14, 2012
Abate by
Apr 4, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1):  The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:    Jobsite:  The employees, engaged in roofing work, were not trained to recognize the hazards of falling and the procedures to follow in order to minimize them.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1060 A

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 14, 2012
Abate by
Apr 4, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a):  The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards.    Jobsite:  The employees, accessing the roof via the erected extension ladder(s), were not trained to recognize the azards related to ladders or the procedures to be followed to minimize the hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 14, 2012
Abate by
Mar 19, 2012
Penalty
Initial $3,000 · Current $1,000 Reduced
29 CFR 1926.102(a)(1):  Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.    Jobsite:  The employees, operating the pneumatic nail guns to fasten the asphalt shingles to the roof, were not provided with eye protection
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3000

1926.404 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 14, 2012
Abate by
Mar 19, 2012
Penalty
Initial $3,000 · Current $1,000 Reduced
29 CFR 1926.404(b)(1)(i):  Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.    Jobsite:  The extension cord, used by the employees to power an electric air compressor and radio, was not GFCI protected.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3000

1926.404 F06

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 14, 2012
Abate by
Mar 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6):  The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    Jobsite:  The ground circuit of the extension cord, used by the employees to power an electric air compressor, was not continuous.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.403 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 14, 2012
Abate by
Mar 19, 2012
Penalty
Initial $3,000 · Current $0 Reduced
29 CFR 1926.403(b)(1)(i):  Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose.    Jobsite:  The four inch wall mount electrical box at the end of the extension cord and powering the air compressor, was not listed, labeled or certified for this type of use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3000

1926.451 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 14, 2012
Abate by
Mar 19, 2012
Penalty
Initial $3,000 · Current $1,000 Reduced
29 CFR 1926.451(c)(2):  Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation:    Jobsite:  The upright poles of the pump-jack scaffold were not bearing on base plates, mud sills or other firm foundation.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3000

1926.451 F03

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 14, 2012
Abate by
Mar 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(3):  Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:    Jobsite:  The pump-jack scaffold, used by the employees engaged in roofing work, was not inspected by a competent person prior to the work shift.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F07

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 14, 2012
Abate by
Mar 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(7):  Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.    Jobsite:  The pump-jack scaffold, used by the employees engaged in roofing work, was not erected under the supervision and direction of a competent person.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 14, 2012
Abate by
Mar 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.452(j)(2):  Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.    Jobsite:  The upright poles, of the pump-jack scaffold used by the employees engaged in roofing work, were not braced by rigid triangular bracing or equivalent at the bottom.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 14, 2012
Abate by
Mar 19, 2012
Penalty
Initial $3,000 · Current $0 Reduced
29 CFR 1926.1053(b)(1):  Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    Jobsite:  The side rails of the two extension ladders, used by the employees to access the elevated pump-jack scaffold platform and the roof, did not extend at least 3 feet beyond the surface accessed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3000

1926.1053 B15

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 14, 2012
Abate by
Mar 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(15):  Ladder(s) were not inspected by a competent person for visible defects on a periodic basis and/or after an occurrence that could have affected their safe use:    Jobsite:  The 32 foot fiberglass extension ladder, used by the employees to access the roof, was not inspected by a competent person periodically.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B16

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 14, 2012
Abate by
Mar 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(16):  Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired.    Jobsite:  The 32 foot fiberglass extension ladder with a delaminating side rail, used by the employees to access the roof, was not tagged "Do Not Use" or taken out of service.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 14, 2012
Abate by
Mar 19, 2012
Penalty
Initial $4,200 · Current $1,400 Reduced
29 CFR 1926.451(g)(1)(vii):  Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    Jobsite:  The employees, walking/working on the elevated platforms of the pump-jack and roof bracket scaffolds, were not protected from the hazard of falling.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $4200

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 14, 2012
Abate by
Mar 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(13):   Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b)  Note:  If using these systems was infeasible or created a greater hazard, the employer should develop and implement a fall protection plan meeting the requirements of paragraph (k) of 1926.502.    Jobsite:   The employees, walking/working on the roof while engaged in roofing activities, were not protected from the hazard of falling to lower levels.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View David Hoyt's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331065326.