OSHA Inspection: PAGO PAGO PURE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PAGO PAGO PURE in BEHIND MOM'S RESTAURANT - AIRPORT TAFUNA, PAGO PAGO, AS 96799 (NAICS 312112). OSHA activity number 331066399.

Watch Pago Pago Pure — free Get an email when a new federal OSHA severe-injury report for Pago Pago Pure is published. One employer, no account, unsubscribe in one click.
Establishment
PAGO PAGO PURE
Site address
BEHIND MOM'S RESTAURANT - AIRPORT TAFUNA
City
PAGO PAGO
State
AS
ZIP
96799
Mailing
P.O. BOX 670, PAGO PAGO, AS 96799
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
312112
Employees
4
Ownership type
A

7 citations on file for this inspection.

1910.37 B02

Serious Gravity 1 3 instances 1 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $1800.00
29 CFR 1910.37(b)(2):     Each exit was not clearly visible and marked by a sign reading "Exit":      a)	Bottling Plant, water filler room: On or about 29 AUG 11, the exit doors at the front, back and the west side were not visibly marked by a sign reading EXIT. The exit sign must be illuminated and visible especially when the room is dark or when the power is off.
Recent events (1)
  • — Z (S) $1800

1910.157 E02

Serious Gravity 1 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $1800.00
29 CFR 1910.157(e)(2):     Portable fire extinguishers were not visually inspected at least monthly:      a) Bottling Plant, compressor room and bottle blower room: On or about 29 AUG 11, several portable fire extinguishers were not inspected monthly to extinguish the hazards involved with incipient stage fire fighting.
Recent events (1)
  • — Z (S) $1800

1910.157 E03

Serious Gravity 1 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(3):     The date of the annual maintenance check of portable fire extinguishers was not recorded:   a)	Bottling Plant, compressor room and bottle blower room: On or about 29 AUG 11, several portable fire extinguishers were not subjected to an annual maintenance check to extinguish the hazards involved with incipient stage fire fighting.
Recent events (1)
  • — Z (S) $0

1910.303 F02

Serious Gravity 1 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $1800.00
29 CFR 1910.303(f)(2):     Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    a)	Bottling Plant, main control panel by north door: On or about 29 AUG 11, power panel did not have a directory to indicate the area serviced by each disconnect exposing employees to contact electricity and shock hazards.     b)	Bottling Plant, main control panel at water tank area operation: On or about 29 AUG 11, power panel did not have a directory to indicate the area serviced by each disconnect exposing employees to contact electricity and shock hazards.
Recent events (1)
  • — Z (S) $1800

1910.305 G01 IV A

Serious Gravity 1 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $1800.00
29 CFR 1910.305(g)(1)(iv)(A):     Flexible cords and cables were used as a substitute for the fixed wiring of a structure.        a)	Compressor room, north and east wall: On or about 29 AUG 11, electrical extension cord (red) originated from the panel box, hangs and runs along the walls to the east cooling fan. The cord was also used as a substitute for fixed wiring exposing employees to contact electricity and shock hazards.
Recent events (1)
  • — Z (S) $1800

1910.305 G01 IV B

Serious Gravity 1 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(B):     Flexible cords and cables were run through holes in walls, ceilings, or floors.      a)	Water tank area, operation: On or about 29 AUG 11, a long red frayed electrical extension cord runs along the floor to power a place fan.  The cord was exposed to foot traffic and forklift exposing employees to contact electricity and shock hazards.
Recent events (1)
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 5 instances 1 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $1800.00
29 CFR 1910.1200(e)(1):     Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): a)	Bottling Plant Operation: On or about 29 AUG 11 and at times prior thereto, a written hazard communication program was not developed, implemented and maintained for hazardous materials such as, but not limited to spray cans containing lubricant, rust inhibitors and grease, stainless steel cleaners and corrosion inhibitors among others.
Recent events (1)
  • — Z (S) $1800

View PAGO PAGO PURE's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331066399.