Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MORRISON, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MORRISON, INC. in 410 COLGATE DR., MARIETTA, OH 45750 (NAICS 332322). OSHA activity number 331067009.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Morrison, INC. — free Get an email when a new federal OSHA severe-injury report for Morrison, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MORRISON, INC.
Site address
410 COLGATE DR.
City
MARIETTA
State
OH
ZIP
45750
Mailing
410 COLGATE DR., MARIETTA, OH 45750
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
32
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 13, 2011
Abate by
Nov 12, 2011
Penalty
Initial $2,975 · Current $2,083 Reduced
29 CFR 1910.147(c)(4)(i):     Procedures shall be developed, documented and utilized for the control of potentially hazardousenergy when employees are engaged in the activities covered by this section. Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the followingelements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down whichcould endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation andlocking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated fromthat energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockoutdevice is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does notcreate hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation orreenergization of the machine or equipment during servicing or maintenance.    a. In the workplace, employee(s) required to service the cutter tip on the Hypertherm Plasma Cutter were not required to utilize the established hazardous energy control procedure for the Hypertherm Plasma Cutter.
Recent events (2)
  • — I (S) $2082.5
  • — Z (S) $2975

1910.147 C07 I

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 13, 2011
Abate by
Nov 12, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i):     The employer shall provide training to ensure that the purpose and function of the energy controlprogram are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls areacquired by employees:      a. In the workplace, employee(s) who the employer had designated "affected" were required to perform maintenance on the Hypertherm Plasma Cutter, and the affected employee(s) were not provided with the knowledge and skills necessary to safely de-energize, isolate, and apply lock out devices, to perform the maintienance safely.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 13, 2011
Abate by
Nov 12, 2011
Penalty
Initial $2,975 · Current $2,083 Reduced
29 CFR 1910.212(a)(3)(ii):     The point of operation of machines whose operation exposes an employee to injury, shall beguarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards,shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operatingcycle.    In the workplace, the Wysong Shear, model 1010-RD, serial number P32-631, was not guarded in that the hold downs had an 1/2 - 5/8" opening, and there was access to the shear blade.
Recent events (2)
  • — I (S) $2082.5
  • — Z (S) $2975

View Morrison, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331067009.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.