Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. GEOLOGICAL SURVEY - RENO, NV

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. GEOLOGICAL SURVEY - RENO, NV in UNIVERSITY OF NEVADA, BLDG 44 1664 N. VIRGINIA STREET, RENO, NV 89503 (NAICS 924120). OSHA activity number 331067512.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Geological Survey - Reno, NV — free Get an email when a new federal OSHA severe-injury report for U.S. Geological Survey - Reno, NV is published. One employer, no account, unsubscribe in one click.
Site address
UNIVERSITY OF NEVADA, BLDG 44 1664 N. VIRGINIA STREET
City
RENO
State
NV
ZIP
89503
Mailing
UNIVERSITY OF NEVADA, BLDG 44 1664 N. VIRGINIA STREET, RENO, NV 89503
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
10000
Ownership type
D

3 citations on file for this inspection.

1910.303 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 21, 2011
Abate by
Nov 25, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a) At the USGS, room 364, a relocatable power tap was used to plug-in high amperage appliances.
Recent events (1)
  • — Z (S) $0

1910.304 B03 I

Serious Gravity 1 2 instances 1 exposed
Issued
Nov 21, 2011
Abate by
Dec 1, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.304(b)(3)(i):     All 125-volt, single-phase, 15- and 20-ampere receptacles installed in bathrooms or on rooftops did not have ground-fault circuit-interrupter protection for personnel.    (a)  At the USGS laboratory room 160A, the duplex convenience outlet receptacles installed in the sink counter did not have GFCI protection.
Recent events (1)
  • — Z (S) $0

1910.36 G02

Other-than-serious 1 instance 3 exposed
Issued
Nov 21, 2011
Abate by
Nov 25, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.36(g)(2):     Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.    (a)  At the USGS room 366, Admin office, the exit access was blocked by chair and supply boxes.
Recent events (1)
  • — Z (O) $0

View U.S. Geological Survey - Reno, NV's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331067512.