Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: MOUNT RAINIER NATIONAL PARK LONGMIRE COMPLEX

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MOUNT RAINIER NATIONAL PARK LONGMIRE COMPLEX in LONGMIRE, LONGMIRE, WA 98397 (NAICS 712190). OSHA activity number 331067728.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mount Rainier National Park Longmire Complex — free Get an email when a new federal OSHA severe-injury report for Mount Rainier National Park Longmire Complex is published. One employer, no account, unsubscribe in one click.
Site address
LONGMIRE
City
LONGMIRE
State
WA
ZIP
98397
Mailing
55210 238TH AVENUE EAST, ASHFORD, WA 98304
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712190
Employees
250
Ownership type
D

11 citations on file for this inspection.

1910.107 B09

Serious Gravity 5 6 exposed
Issued
Oct 11, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(9):  A clear space of not less than 3 feet on all sides of the spray booth was not kept free from storage or combustible construction:    a)  Sign Shop;  Items including but not limited to paint filters, boxes of papers, wood, and a trash can were stored within 3 feet of the Binks Paint Spray Booth.
Recent events (1)
  • — Z (S) $0

1910.107 E02

Serious Gravity 5 6 exposed
Issued
Oct 11, 2011
Abate by
Nov 10, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.107(e)(2):  Bulk storage of portable containers of flammable or combustible liquids was not in a separate, constructed building detached from other important buildings or cut off in a standard manner.    a)  Sign Shop;  A yellow flammable storage cabinet filled with paint and spray paint was located 4 feet from the paint spray booth in the same room.
Recent events (1)
  • — Z (S) $0

1910.147 C04 I

Repeat Gravity 5 6 exposed
Issued
Oct 11, 2011
Abate by
Nov 10, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:                                                                                                                                 a)  Specific lockout tagout step-by-step procedures were not developed for boilers and air compressors which have stored energy.     The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 309098275, citation 1,  item 2A, issued on September 22, 2010 with respect to a workplace at Stehekin, WA.     The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 309096139, citation 1,  item 1A, issued on September 9, 2009 with respect to a workplace at Newhalem, WA.     The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 309096162, citation 2,  item 3A, issued September 9, 2009 with respect to a workplace at Marblemount, WA.
Recent events (1)
  • — Z (R) $0

1910.147 C06 II

Repeat Gravity 5 6 exposed
Issued
Oct 11, 2011
Abate by
Nov 10, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer did not certify that the periodic inspections of the lockout tagout program had been performed.  The certification did not identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.    a)  An annual review and certification of lockout tagout procedures were not completed for boilers and air compressors.     The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 309098275, citation 1,  item 2B, issued on September 22, 2010 with respect to a workplace at Stehekin, WA.     The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 309096139, citation 1,  item 1B, issued on September 9, 2009 with respect to a workplace at Newhalem, WA.      The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 309096162, citation 2,  item 3B, issued September 9, 2009 with respect to a workplace at Marblemount, WA.
Recent events (1)
  • — Z (R) $0

1910.212 A01

Repeat Gravity 5 6 exposed
Issued
Oct 11, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1):  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a)  Carpentry Shop;  The 10" Ryobi table saw did not have a guard over the saw blade.     The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 309096154 citation 2, item 1, issued on September 9, 2009 with respect to a workplace at Marblemount, WA.
Recent events (1)
  • — Z (R) $0

1910.212 B

Repeat Gravity 5 6 exposed
Issued
Oct 11, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:                                                                                                                        a)  Sign Shop;  The Orbit drill press was not mounted to the floor or securely attached to base which would prevent movement.     The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 309094332 citation 2, item 1, issued on September 23, 2008 with respect to a workplace at Port Angeles, WA.
Recent events (1)
  • — Z (R) $0

1910.215 B09

Repeat Gravity 5 6 exposed
Issued
Oct 11, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9):  The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    a)  Auto Shop/ Welding Area; The Bitco grinder had it's tongue guard approximately 1 inch from the grinding stone on the right side of the grinder.     The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 309096162 citation 2, item 7, issued on September 9, 2009 with respect to a workplace at Marblemount, WA    The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 30904316 citation 2, item 2, issued on October 3, 2008 with respect to a workplace at Port Angeles, WA.    The National Park Service was previously cited for a violation of this standard which was contained in OSHA inspection no. 30904209 citation 2, item 1, issued on August 15, 2008 with respect to a workplace at Port Angeles, WA.
Recent events (1)
  • — Z (R) $0

1910.157 C01

Other-than-serious 6 exposed
Issued
Oct 11, 2011
Abate by
Nov 10, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located   and identified so that they were readily accessible without subjecting the employees to injuries:    a)  Auto Shop;  The Buckeye fire extinguisher was blocked from access by a table.
Recent events (1)
  • — Z (O) $0

1910.157 E02

Other-than-serious 6 exposed
Issued
Oct 11, 2011
Abate by
Nov 10, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2):  Portable fire extinguishers were not visually inspected at least monthly:    a)  Longmire Complex; Fire extinguishers including but not limited to the Buckeye fire extinguisher in the Electrical Shop, the Amerex Fire Extinguisher in the Carpentry Shop, and the Buckeye fire extinguisher in the Auto Shop had not undergone monthly visual inspections.
Recent events (1)
  • — Z (O) $0

1910.157 E03

Other-than-serious 6 exposed
Issued
Oct 11, 2011
Abate by
Nov 10, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3):  Portable fire extinguishers were not subjected to an annual maintenance check:    a)  Longmire Complex; Fire extinguishers including but not limited to the Buckeye fire extinguisher in the Electrical Shop, the Amerex Fire Extinguisher in the Carpentry Shop, and the Buckeye fire extinguisher in the Auto Shop had not undergone annual maintenance checks since October 2008.
Recent events (1)
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 6 exposed
Issued
Oct 11, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii):  Working space about electric equipment rated 600 volts, nominal, or less was used for storage:    a)  Carpentry Shop;  A planer, wood table, wooden bench and saws were stored directly in front of the breaker panel.     b)  Paint Storage Shop;  Stacks of wood, a stereo, rake, axes and a chair were stored underneath the breaker panel.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331067728.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.