APPLETON, WI ·
OSHA Inspection: CALLAWAY CONSTRUCTION INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CALLAWAY CONSTRUCTION INC in 736 EIGHTH ST, APPLETON, WI 54911 (NAICS 238160). OSHA activity number 331068197.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CALLAWAY CONSTRUCTION INC
- Site address
- 736 EIGHTH ST
- City
- APPLETON
- State
- WI
- ZIP
- 54911
- Mailing
- W866 AKRON RD, WEYAUWEGA, WI 54983
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1926.102 A01
- Issued
- Dec 19, 2011
- Abate by
- Dec 20, 2011
- Penalty
- Initial $3,000 · Current $1,600 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: An employee was utilizing a pneumatic nail gun during roofing work without wearing eye protection. No Abatement Certification of Abatement Documentation required
Recent events (2)
- · I (S) $1600
- · Z (S) $3000
1926.301 A
- Issued
- Dec 19, 2011
- Abate by
- Dec 27, 2011
- Penalty
- Initial $3,000 · Current $1,600 Reduced
General-duty citation text
29 CFR 1926.301(a): Unsafe hand tool(s) were issued or permitted to be used: Employees who were installing sheeting on a roof were utilizing a Porter Cable circular saw which had copper showing in the damaged flexible cord and was plugged in and ready for use. No Abatement Certification or Abatement Documentation required
Recent events (2)
- · I (S) $1600
- · Z (S) $3000
1926.403 B02
- Issued
- Dec 19, 2011
- Abate by
- Dec 27, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: Employees were using two metal handy boxes connected together as a single eight plug unit to power a radio, compressor, and circular saw; the handy box unit received feed from a 110V garage wall receptacle through an extension cord and it was positioned outside and on the ground. No Abatement Certification or Abatement Documentation required.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.405 G02 IV
- Issued
- Dec 19, 2011
- Abate by
- Dec 27, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: Employees who were performing roofing work were utilizing a blue extension cord without strain relief on the male plug end which was plugged into a 110V wall receptacle. No Abatement Certification or Abatement Documentation required
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.416 E01
- Issued
- Dec 19, 2011
- Abate by
- Dec 27, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) Employees who were performing roofing work were using a blue extension cord with breaks and cuts in the insulation to feed a metal handy box unit from a 110V garage wall receptacle. b) Employees who were performing roofing work were using a black 12 foot extension cord with breaks and cuts in the insulation to feed a hand held circular saw from a metal handy box unit. No Abatement Certification or Abatement Documentation required
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.501 B11
- Issued
- Dec 19, 2011
- Abate by
- Dec 20, 2011
- Penalty
- Initial $2,400 · Current $1,150 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: An employee was working on an 8:12 pitch roof with an eave edge greater than 6.5 feet above compacted surface without utilizing adequate fall protection equipment. No Abatement Certification or Abatement Documentation required
Recent events (2)
- · I (S) $1150
- · Z (S) $2400
1926.1053 B01
- Issued
- Dec 19, 2011
- Abate by
- Dec 20, 2011
- Penalty
- Initial $2,400 · Current $1,150 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladders length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigied support that will not deflect, and/or a grasping device was not provided to assist emmployees in mounting and dismounting the ladder: Employees used a Werner six (6) foot self supporting step ladder to access/egress a roof work surface with an eave edge greater then six and one half (6.5) feet above concret surface without any grab rails above the upper landing surface. No Abatement Certification or Abatement Documentation required.
Recent events (2)
- · I (S) $1150
- · Z (S) $2400
1926.1053 B13
- Issued
- Dec 19, 2011
- Abate by
- Dec 20, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or step of a stepladder was used as a step: Employee was using the top of a six foot Werner self supporting step ladder as a step to access/egress a roof work surface and/or scaffold planking. No Abatement Certification or Abatement Documentation required.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Callaway Construction INC
View Callaway Construction INC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331068197.