OSHA Inspection: U.S. DEPT OF VETERANS AFFAIRS - WEST LOS ANGELES MEDICAL CENTER

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. DEPT OF VETERANS AFFAIRS - WEST LOS ANGELES MEDICAL CENTER in 11301 WILSHIRE BLVD, LOS ANGELES, CA 90073 (NAICS 622110). OSHA activity number 331071464.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Dept of Veterans Affairs - West LOS Angeles Medical Center for free Get an email when a new federal OSHA severe-injury report for U.S. Dept of Veterans Affairs - West LOS Angeles Medical Center is published. One employer, no account, unsubscribe in one click.
Site address
11301 WILSHIRE BLVD
City
LOS ANGELES
State
CA
ZIP
90073
Mailing
11301 WILSHIRE BLVD., LOS ANGELES, CA 90073
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
622110
Employees
3000
Ownership type
Federal government (D)

16 citations on file for this inspection.

1910.23 E02

Serious Gravity 5 1 instance 15 exposed
Issued
Jan 20, 2012
Abate by
Feb 10, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.23(e)(2): Stair rails did not consist of a top rail, intermediate rail and/or posts, with the vertical height not more than 34 inches (86.36 cm) nor less than 30 inches (76.2 cm) from upper surface of top rail to surface of tread in line with face of riser at forward edge of tread:    Building 44, Engineering shops - On or about October 11, 2011, The stair railing leading on the stairs leading from the ground floor to the uppper floor break room was constructed without a mid rail, and with a vertical height of 37 inches from the stair rail to the surface of the tread.
Recent events (1)
  • · Z (S) $0

1910.36 G02

Serious Gravity 5 4 instances 51 exposed
Issued
Jan 20, 2012
Abate by
Feb 10, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.    (a) Building 500, Pharmacy After Hours Dispensing Room - On or about September 29, 2011, The employer placed an employee work station and trash container in the exit access restricting the access to approximately 18 inches.    (b) Building 500, IV Room - On or about September 29, 2011, The employer obstructed the exit access by placing large cabinets against the door leading from the room, the exit access was restricted to approximately 15 inches.    (c) Building 500, Phlebotomy, Room 224 - On or about October 11, 2011, The employer placed a filing desk and hazardous waste disposal bin in the exit access restricting the access to approximately 18 inches.    (d) Building 500, Uniform Room - On or about October 12, 2011, The employer placed a work table in the exit access to prevent other personnel from entering the room, in doing so, the exit access for employees working in the uniform room was blocked.
Recent events (1)
  • · Z (S) $0

1910.147 C06 I C

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 20, 2012
Abate by
Feb 10, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected:    Laundry Facility, Building 508 - On or about October 12, 2011, The employer allowed an employee to perform lockout procedures on the #2 Small Piece Folder on October 7, 2011 at 8:00 am without reestablishing employee proficiency with annual retraining.
Recent events (1)
  • · Z (S) $0

1910.176 B

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.176(b): Storage of material created a hazard:    Warehouse loading dock, Building 297 - On or about October 11, 2011, Six large compressed gas cylinders, three containing 228 cu ft of Nitrogen, three containing 50 lbs Carbon Dioxide, and 91 smaller cylinders containing 24 cu ft of Oxygen were standing upright without bracing or other support to prevent their falling over.
Recent events (1)
  • · Z (S) $0

1910.178 A04

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 20, 2012
Abate by
Feb 10, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation shall not be performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly.    Building 510, Garage - On or about October 11, 2011, An additional seat was provided for employee transport on the right fender of a Clark Tractor Model FCT40RS, SN 696140RR124RS, a type VI powered industrial truck, without prior written approval from the manufacturer.
Recent events (1)
  • · Z (S) $0

1910.178 L01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 20, 2012
Abate by
Feb 10, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l)    Building 510, Garage - On or about October 11, 2011, Employees were provided a Clark Tractor Model FCT40RS, SN 696140RR124RS, a type VI powered industrial truck, for use, the employees were not trained for the use of this vehicle.
Recent events (1)
  • · Z (S) $0

1910.215 A04

Serious Gravity 5 2 instances 4 exposed
Issued
Jan 20, 2012
Abate by
Feb 10, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    (a) Building 44, Engineering shops - On or about October 11, 2011, The right side work rest of a Rockwell model 691EE21309, SN 1752982 grinder measured one quarter inch (1/4") from the grinder wheel.    (b) Building 44, Engineering shops - On or about October 11, 2011, The right side work rest of a Baldor grinder labeled: VA Property 3415-5033 measured seven sixteenths inch (7/16") from the grinder wheel.
Recent events (1)
  • · Z (S) $0

1910.215 B09

Serious Gravity 5 4 instances 4 exposed
Issued
Jan 20, 2012
Abate by
Feb 10, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    (a) Building 44, Engineering shops - On or about October 11, 2011, The right side tongue guard of a Rockwell Model 691EE21309, SN 1752982 grinder measured seven sixteenths inch (7/16") from the grinder wheel.    (b) Building 44, Engineering shops - On or about October 11, 2011, The right side work rest of a Baldor grinder labeled: VA Property 3415-5033 measured thirteen sixteenths inch (13/16") from the grinder wheel.    (c) Building 44, Engineering shops - On or about October 11, 2011, The left and right side tongue guards of a Cincinnati Model 104, SN 136190 grinder measured one half and three eighths inches (1/2" & 3/8") respectively from the grinder wheel.    (d) Building 510, Garage - On or about October 11, 2011, The left side tongue guard of a Blue-Point Model BG750-B, SN LR15562 grinder was askew and not adjusted to within one quarter inch of the grinder wheel.
Recent events (1)
  • · Z (S) $0

1910.215 D03

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 20, 2012
Abate by
Feb 10, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.215(d)(3): The contact surface(s) of wheel(s), blotter(s) or flange(s) on grinding machine(s) were not flat and free or foreign matter:    Building 510, Garage - On or about October 11, 2011, The left side grinding wheel surface on a Stoney Craft grinder Model HG8A, SN 93028 was impregnated with brass.
Recent events (1)
  • · Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    Building 44, Engineering shops - On or about October 11, 2011, The employer allowed employees to use a gray flexible cord set with the grounding pin removed, exposing the employees to shock and electrocution hazards.
Recent events (1)
  • · Z (S) $0

1910.303 G02 I

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 20, 2012
Abate by
Feb 10, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    Building 500, Pharmacy Hallway - On or about September 29, 2011, An electrical receptacle providing 115VAC service was not protected by a cover, exposing employees to inadvertent contact with the live conductors.
Recent events (1)
  • · Z (S) $0

1910.305 G01 IV B

Serious Gravity 5 1 instance 15 exposed
Issued
Jan 20, 2012
Abate by
Feb 10, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors:    Building 44, Engineering Shops - On or about October 11, 2011, Two orange colored flexible cord sets were run through the wall of the building to provide electrical service to the battery powered carts used by the employees.
Recent events (1)
  • · Z (S) $0

1910.305 G01 IV C

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 20, 2012
Abate by
Feb 10, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were run through doorways, windows, or similar openings:    Building 510, Garage - On or about October 11, 2011, A flexible cord was run under a closed garage door to provide electrical service to carts outside the building.
Recent events (1)
  • · Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    Building 44, Engineering shops - On or about October 11, 2011, The employer allowed an employee to use a gray flexible cord set with the outer sheath of the cord insulation pulled back exposing the conductors inside and transferring pull on the cord directly to the terminal screws.
Recent events (1)
  • · Z (S) $0

1910.305 J02 V

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 20, 2012
Abate by
Feb 10, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(2)(v): A receptacle installed outdoors in a location protected from the weather or in other damp locations did not have an enclosure for the receptacle that was weatherproof when the receptacle was covered (attachment plug cap not inserted and receptacle covers closed):    Building 500, Loading Dock - On or about October 11, 2011, An electrical receptacle outlet was of a type suitable for indoor installations and did not have en enclosure to cover the outlet.
Recent events (1)
  • · Z (S) $0

1910.146 E01

Repeat Gravity 5 1 instance 3 exposed
Issued
Jan 20, 2012
Abate by
Feb 10, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.146(e)(1): Before entry was authorized, the employer did not document the completion of measures required by 29 CFR 1910.146(d)(3) by preparing an entry permit:    Building 295, Boiler room - On or about October 12, 2011, An employee entered a boiler, a permit required space, without the employers documentation of conditions for the entry.    The Department of Veterans Affairs was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.146(e)(1) which was contained in OSHA inspection number 101962 (NCR 315053777), citation number 1, item number 1, and was affirmed as a final order on May 1, 2011 with respect to a workplace located at 5901 East 7th Street, Long Beach, CA 90822.
Recent events (1)
  • · Z (R) $0

View U.S. Dept of Veterans Affairs - West LOS Angeles Medical Center's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331071464.