OSHA Inspection: GLACIER CONSTRUCTION CO., INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GLACIER CONSTRUCTION CO., INC. in 1201 ASH AVE., GREELEY, CO 80631 (NAICS 236210). OSHA activity number 331072082.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Glacier Construction CO., INC. for free Get an email when a new federal OSHA severe-injury report for Glacier Construction CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
1201 ASH AVE.
City
GREELEY
State
CO
ZIP
80631
Mailing
8490 E CRESCENT PKWY, SUITE 250, GREENWOOD VILLAGE, CO 80111
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
Employees
25
Ownership type
Private (A)

3 citations on file for this inspection.

1910.134 D01 III

Deleted Other-than-serious 1 instance 2 exposed
Issued
Mar 19, 2012
Abate by
Apr 3, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace: (Construction Reference 1926.103)    (a) Glacier Construction Co., Inc. at 1201 Ash Ave., Greeley, CO 80631: The employer did not identify and evaluate the respiratory hazards in the workplace. Employees are cutting into the concrete building and grinding on pipes. The employer did not evaluate employee exposure to the respiratory hazards. This condition exposed employees to inhalation hazards such as but not limited to respirable crystalline silica and various metal particulates.     Abatement Note: Paragraph K requires the employer to provide effective training to employees who are required to use respirators. The employer is also required to provide the basic information on respirators in Appendix D to employees who wear respirators when not required by the employer to do so.        Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.134 E01

Deleted Other-than-serious 1 instance 2 exposed
Issued
Mar 19, 2012
Abate by
Apr 3, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace.       (a) Glacier Construction Co., Inc. at 1201 Ash Ave., Greeley, CO 80631: On and before 9/28/11, the employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. Employees performing hand grinding and concrete cutting were exposed to respirable silica. Employees were using filtering facepiece respirators and half face respirator. This condition exposed employees to the physiological hazard of wearing respiratory protection without proper evaluation by a physician or other licensed health care professional.       Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.146 C02

Deleted Other-than-serious 1 instance 2 exposed
Issued
Mar 19, 2012
Abate by
Apr 3, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces:    (a)	Glacier Construction Co., Inc. at 1201 Ash Ave., Greeley, CO 80631: On and before 9/28/11, the employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by permit spaces. The tanks on site had been evaluated as permit required spaces. Employers did not identify these spaces by posting danger signs or by any other equally effective means. This condition exposed the employees to a confined space hazard.        Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Glacier Construction CO., INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331072082.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.