EAU CLAIRE, WI —
OSHA Inspection: PHILLIPS PLASTICS CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PHILLIPS PLASTICS CORPORATION in 2930 MONDOVI ROAD, EAU CLAIRE, WI 54701 (NAICS 332312). OSHA activity number 331072488.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PHILLIPS PLASTICS CORPORATION
- Site address
- 2930 MONDOVI ROAD
- City
- EAU CLAIRE
- State
- WI
- ZIP
- 54701
- Mailing
- 2930 MONDOVI ROAD, EAU CLAIRE, WI 54701
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 90
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 I
- Issued
- Feb 6, 2012
- Abate by
- Mar 30, 2012
- Penalty
- Initial $3,000 · Current $5,400
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Horizontal injection molding machine JSW 850; The written machine specific lockout procedure did not include procedures to control the stored thermal energy of the liquid magnesium.
Recent events (2)
- — I (S) $5400
- — Z (S) $3000
1910.147 C04 II B
- Issued
- Feb 6, 2012
- Abate by
- Mar 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps shall be developed for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: (a) Horizontal injection molding machine JSW 850; Procedural elements and actions were not performed in the required sequence to isolate or dissipate the stored thermal energy of the liquid magnesium while conducting maintenance activities.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C04 II C
- Issued
- Feb 6, 2012
- Abate by
- Mar 30, 2012
- Penalty
- Initial $6,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(C): Specific procedural steps shall be developed for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them: (a) Horizontal injection molding machine JSW-1; Employees relied on electrical interlocks while conducting servicing and/or maintenance tasks without specific procedures.
Recent events (2)
- — I (S) $0
- — Z (S) $6000
1910.305 B01 II
- Issued
- Feb 6, 2012
- Abate by
- Feb 13, 2012
- Penalty
- Initial $5,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) Electrical panel JSW-2; The open dead front of the electrical panel was covered with duct tape. (b) Electrical panel JSW-1; The open space for a circuit breaker was covered with duct tape.
Recent events (2)
- — I (S) $3000
- — Z (S) $5000
More inspections at Phillips Plastics Corporation