LAKEWOOD, WA —
OSHA Inspection: U.S. GEOLOGICAL SURVEY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of U.S. GEOLOGICAL SURVEY in 8914 LAKEVIEW AVE SW, LAKEWOOD, WA 98499 (NAICS 921190). OSHA activity number 331073288.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. GEOLOGICAL SURVEY
- Site address
- 8914 LAKEVIEW AVE SW
- City
- LAKEWOOD
- State
- WA
- ZIP
- 98499
- Mailing
- 934 BROADWAY SUITE 300, TACOMA, WA 98402
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 921190
- Employees
- 75
- Ownership type
- D
Citations
7 citations on file for this inspection.
1910.101 B
- Issued
- Oct 26, 2011
- Abate by
- Nov 2, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, was not in accordance with Compressed Gas Association Pamphlet P-1-1965, which was incorporated by reference as specified in 29 CFR 1910.6: a) In the Boat Garage there was a storeed nitrogen cylinder that was unsecured.
Recent events (1)
- — Z (S) $0
1910.212 B
- Issued
- Oct 26, 2011
- Abate by
- Dec 9, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machines designed for fixed locations were not securely anchored to prevent walking or moving: a) In the Carpenter Shop the Walker Turner Drill Press was not secured to the work bench.
Recent events (1)
- — Z (S) $0
1910.213 C03
- Issued
- Oct 26, 2011
- Abate by
- Dec 9, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(3): Handfed ripsaw(s) did not have non kickback fingers or dogs designed to provide adequate holding power for all thicknesses of materials being cut: a) In the Carpenter Shop the Rockwell table saw sn334699 did not have non-kickback dogs.l
Recent events (1)
- — Z (S) $0
1910.213 H01
- Issued
- Oct 26, 2011
- Abate by
- Dec 9, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw was not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the meterial. a) In the Carpenter Shop the Dewalt radial arm saw Model GE sn9631 did not have a lower blade guard.
Recent events (1)
- — Z (S) $0
1910.253 B02 II
- Issued
- Oct 26, 2011
- Abate by
- Dec 9, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials, a minium distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire resistance rating of at least one-half hour. (a) In the Welding Shop oxygen and acetylene bottles were stored together.
Recent events (1)
- — Z (S) $0
1910.303 G02 I
- Issued
- Oct 26, 2011
- Abate by
- Dec 9, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) The electrical panel in Gas Station was open and damaged allowing exposure to live electrical parts. b) Florescent tube lights in warehouse next to storage shelves were not guarded. c) Throughout warehouse screw in florescent lights did not have guards to protect them against breaking.
Recent events (1)
- — Z (S) $0
1910.305 G02 III
- Issued
- Oct 26, 2011
- Abate by
- Dec 9, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: (a) In the Welding Shop the power cord for drill press was deamaged in that the outer insulation sleve had pulled loose from the plug allowing stress to be transmitted to the terminal screws should the cord be pulled.
Recent events (1)
- — Z (S) $0
More inspections at U.S. Geological Survey
View U.S. Geological Survey's full OSHA safety record →
More inspections in this industry (NAICS 921190)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331073288.