Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. GEOLOGICAL SURVEY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. GEOLOGICAL SURVEY in 8914 LAKEVIEW AVE SW, LAKEWOOD, WA 98499 (NAICS 921190). OSHA activity number 331073288.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Geological Survey — free Get an email when a new federal OSHA severe-injury report for U.S. Geological Survey is published. One employer, no account, unsubscribe in one click.
Site address
8914 LAKEVIEW AVE SW
City
LAKEWOOD
State
WA
ZIP
98499
Mailing
934 BROADWAY SUITE 300, TACOMA, WA 98402
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
921190
Employees
75
Ownership type
D

7 citations on file for this inspection.

1910.101 B

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 26, 2011
Abate by
Nov 2, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.101(b):  The in-plant handling, storage, and utilization of all compressed gases in cylinders, was not in accordance with Compressed Gas Association Pamphlet P-1-1965, which was incorporated by reference as specified in 29 CFR 1910.6:    a) In the Boat Garage there was a storeed  nitrogen cylinder that was unsecured.
Recent events (1)
  • — Z (S) $0

1910.212 B

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 26, 2011
Abate by
Dec 9, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b):  Machines designed for fixed locations were not securely anchored to prevent walking or moving:    a) In the Carpenter Shop the Walker Turner Drill Press was not secured to the work bench.
Recent events (1)
  • — Z (S) $0

1910.213 C03

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 26, 2011
Abate by
Dec 9, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(3):  Handfed ripsaw(s) did not have non kickback fingers or dogs designed to provide adequate holding power for all thicknesses of materials being cut:    a) In the Carpenter Shop the  Rockwell table saw sn334699 did not have non-kickback dogs.l
Recent events (1)
  • — Z (S) $0

1910.213 H01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 26, 2011
Abate by
Dec 9, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.213(h)(1):  The sides of the lower exposed portion of the blade of radial saw was not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the meterial.    a) In the Carpenter Shop the Dewalt radial arm saw Model GE sn9631 did not have a lower blade guard.
Recent events (1)
  • — Z (S) $0

1910.253 B02 II

Serious Gravity 1 1 exposed
Issued
Oct 26, 2011
Abate by
Dec 9, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii):  Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials, a minium distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire resistance rating of at least one-half hour.    (a) In the Welding Shop oxygen and acetylene bottles were stored together.
Recent events (1)
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 1 3 instances 1 exposed
Issued
Oct 26, 2011
Abate by
Dec 9, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    a) The electrical panel in Gas Station was open and damaged allowing exposure to live electrical parts.    b) Florescent tube lights in warehouse next to storage shelves were not guarded.    c) Throughout warehouse screw in florescent lights did not have guards to protect them against breaking.
Recent events (1)
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 exposed
Issued
Oct 26, 2011
Abate by
Dec 9, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii):  Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    (a) In the Welding Shop the power cord for drill press was deamaged in that the outer insulation sleve had pulled loose from the plug allowing stress to be transmitted to the terminal screws should the cord be pulled.
Recent events (1)
  • — Z (S) $0

View U.S. Geological Survey's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331073288.