OSHA Inspection: CSG EXTERIOR LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of CSG EXTERIOR LLC in 403 N 150 W, BLACKFOOT, ID 83221 (NAICS 238160). OSHA activity number 331073726.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CSG Exterior LLC — free Get an email when a new federal OSHA severe-injury report for CSG Exterior LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CSG EXTERIOR LLC
Site address
403 N 150 W
City
BLACKFOOT
State
ID
ZIP
83221
Mailing
598 W. 2760 N., PLEASANT GROVE, UT 84062
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
40
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 3 exposed
Issued
Jan 24, 2012
Abate by
Feb 14, 2012
Penalty
Initial $1,800 · Current $1,800
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury:                                                                                                              (a)	Worksite:  On September 22, 2011, four employees operating pneumatic nail guns were not wearing eye protection.     Note: Abatement certification IS required for this item.
Recent events (1)
  • — Z (S) $1800

1926.501 B11

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 24, 2012
Abate by
Feb 14, 2012
Penalty
Initial $2,400 · Current $2,400
29 CFR 1926.501(b)(11):     Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:      (a)	North Side of Roof: On September 22, 2011, two employees were exposed to a fall hazard of approximately nine feet to the ground while working on a 5:12 slope roof.      Note: Abatement certification IS required for this item.
Recent events (1)
  • — Z (S) $2400

1926.403 B01 I

Other-than-serious 1 instance 3 exposed
Issued
Jan 24, 2012
Abate by
Feb 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(1)(i): Listed or labeled electrical equipment was not used or installed in   accordance with instructions included in the listing or labeling:    (a)	Worksite:  On September 22, 2011, employees constructed and used an extension cord apparatus made from an electrical cord and a four-outlet metal junction box.     Note: Abatement certification IS required for this item.